5
DIMENSIONAL DATA
"H" in. [mm] "W" in. [mm] "L" in. [mm] Liquid in. Suction in.
29-1/8[740] 29-1/8[740]
29-1/8[740] 29-1/8[740]
29-1/8[740] 29-1/8[740]
29-1/8[740] 29-1/8[740]
MODEL SIZE
Dimensions (Inches)
Refrigerant Connection
Service Valve Size
24-15/16[633]
3/8
3/8
3/8
3/8
3/4
3/4
7/8
7/8
24-15/16[633]
33-3/16[843]
33-3/16[843]
36
36
AC
HP
24
24
48
48
60
60
FIG.2 DIMENSIONS
SUCTION LINE
CONNECTION
CONTROL WIRING
7/8” (22.2mm)
KNOCKOUT
1-11/32” (34.5mm)
LIQUID LINE
CONNECTION
SERVICE
FITTING
SERVICE
FITTING
POWER WIRING
SEE DETAIL A
DETAIL A
HOLE
1-3/32” (27.8mm)
NOTE:
GRILL APPEARANCE
MAY VARY.
NOTES: 1
.
AC: Air Conditioner; HP: Heat Pump;
AIR DISCHARGE:
ALLOW 60”
MINIMUM CLEARANCE.
SERVICE ACCESS
ALLOW 24” CLEARANCE
AIR INLETS
LOUVERED PANELS
ALLOW 18”
MINIMUM
CLEARANCE
W