24
Display content Error or protection definition
Remark
E4
Temp. sensor error
E5
Voltage protection(overvoltage and undervoltage)
Self-recovery for the first voltage protection, second voltage
protection needs to be pow ered on and then recover.
E6 DC
motor
error
Eb
2 E6 protections in 10 min
Recover w hen pow ering on again
E7
Air discharge sensor T5 loosely-inserted error
H0
Main control chip and comm. Chip comm. error
H3
3 (P3) protections in 120 min
Recover w hen pow ering on again
H4
3 (P6) protections in 60 min
Recover when powering on again
H5
5 (P2) protections in 100 min
Recover when powering on again
H6
3 (P4) protections in 100 min
Recover when powering on again
H8 Pressure
sensor
error
Hb
Heating high pressure protection
HH
PH standby tw ice in 200 min.
Recover when powering on again
P0
Module radiator temp. Tf protection
P1
High pressure protection
P2 Low
pressure
protection
P3
frequency-conversion over-current protection
P4
Air discharge overtemperature protection
Cooling high pressure protection
(T3 pipe high temp.)
P6
Compressor instant over-current protection
PH
Compressor liquid –return protection
P8
DC fan typhoon protection
After 2 min, it w ill recover to normal status.
C3
T3 sensor loosely-inserted error
CE
5 P1 protections in 150min
Recover when powering on again
F1
High pressure protection sw itch error
F3
5 P5 protections in 180min
Recover when powering on again
F4
3 P0 protections in 120min
Recover when powering on again
5 Hb protections in 180min
Recover when powering on again
Frequency limited/status definition
D
T5 high temp. protection frequency limit
P
Compression ratio protection frequency limit
F
Module temp. protection frequency limit
C
Current protection frequency limit
U
Voltage
protection
frequency
limit
H
Condensing pressure protection frequency limit
A
Oil
return
dF Defrost
T3 high temp. protection frequency limit
L
F5
P5
8.5 Error code table