XW-HTP550
36
1
2
3
4
1
2
3
4
C
D
F
A
B
E
(1) In a case where the power is not turned on (the POWER LED does not light)
2. Receiver (Wireless SP) side
No power
(The POWER LED does not light.)
Check that the circuits
are not short-circuited.
(
*
1) : FFC between CN5901 (RX Assy) and CN5902 (LED Assy)
Is the
FFC (
*
1) correctly
inserted?
Is the fuse FU1 blown?
Is the
IC11 and/or IC14
in MAIN Assy
broken?
Insert the FFC
correctly.
Replace the FU1 fuse.
No
No
No
No
No
No
Yes
Is the
POWER LED lit?
Yes
Yes
Is the POWER
LED lit?
Yes
Yes
Is the POWER
LED lit?
Yes
Yes
Replace IC11 and/or
IC14.
Yes
Inspection completed.
As the circuit for +9 V is most
likely to have been short-
circuited, check the circuits
around IC15.
(2) In a case where no sound is output
No sound
Is TUNED LED
lit?
Is the relay on?
Check the "SP PROTECT"circuits
around Q3455 and Q3454.
No
Check the Transmitter side.
No
Yes
Yes
Replace IC12
and IC13.
Is +B voltage active?
No
Yes
(A)