XV-EV51
94
1
2
3
4
1
2
3
4
C
D
F
A
B
E
DC power-
supply
V
A
Single purpose operation method.
1
7
SINGLE OPERATION METHOD
Jigs and Measuring instruments
2
Supply a DC power while short-circuiting the jumpers (W282 and W285) with "SERVICE" indication on the IF Assy.
Supply DC power to each point, and all the divided GND short-circuits.
DC apply point
IGND short circuit point
Locations
GND Name
Assy Name
1
CN8901 16PIN
GNDD
AF ASSY
2
W132
GNDA
AF ASSY
3
W395
GNDM
IF ASSY
Voltage
Locations
Apply Point Name
Assy Name
1
8V
W497
IC5508 IN
IF Assy
2
8V
W264
V+8V
IF Assy
3
16V
C8902 + side VU+12V
AF Assy
Individual operation method of XV-EV51,EV21 (MEDIA)
STOP
All Operations
TEST MODE : STOP
→
CANCEL
The DC power supply
(+8.0V) is turned off.
+8.0V
DC power-
supply
V
A
off
Power SW
DC Output (+8.0V)
GND
S
T.
M
E
M
O
R
Y
· S
TO
P
7
IF ASSY