36
20
23.02 24.93 26.97
74
2.921 3.033 3.146
128
0.5818 0.6148 0.649
21
22.04 23.84 25.77
75
2.827 2.933
3.04
129
0.5667 0.5991 0.6328
22
21.1 22.81 24.63
76
2.735 2.836 2.938
130
0.5521 0.5839 0.6171
23
20.21 21.83 23.55
77
2.647 2.743
2.84
Appendix 3
Silk-printed label on outdoor control board of inverter unit
Control board connection
Connector label
Description label
Relay label
Remarks
AC power incoming wire L
P1
AC-L
AC power incoming wire N
P2
AC-N
It is required to
reserve 4 inserts at
least
To indoor communication wire
P3
S
Ground wire
P0
GND
Outgoing wire L after filter
P4
L
K1
Relay control
Outgoing wire N after filter
P5
N
For multiple wires,
use P5-1 and P5-2
to identify.
DC+ input
P6-1
DC+
DC- input
P7-1
DC-
DC+ output
P6-2
DC+
DC- output
P7-2
DC-
4-way valve output
P8
VAL
K4
Outdoor fan HI output
P9-1
H
K2
Outdoor fan LOW output
P9-2
L
K3
Outdoor fan capacitor
P9-3
C
Compressor output phase-U
P10-1
U
Compressor output phase-V
P10-2
V
Compressor output phase-W
P10-3
W
Module DC+ input
P6B
DC+
Intelligent
power
module
Module DC- input
P7B
DC-
Intelligent
power
module
PFC board rectified input +
(Direct-insert bridge AC input)
P11 DC+
Power
factor
correction
PFC board rectified input -
(Direct-insert bridge AC input)
P12 DC-
Power
factor
correction
PFC inductance interface
P13
、
P14 L
Power factor
correction
PFC DC+ output
P6C
DC+
Power
factor
correction
PFC DC- output
P7C
DC-
Power
factor
correction
Outdoor fan DC motor socket
CN9
Outdoor temperature sensor
CN1
Exhaust pipe temperature sensor
CN2
Suction pipe temperature sensor
CN10
Compressor top thermostat
CN3
Summary of Contents for WD Series