(3) Display E3, E7, E8
Symptom
Display E3, E7, E8
Cause
Outdoor pipe (coil) temperature sensor and
outdoor temperature sensor and exhaust
temperature sensor fault
S/N
Inspections
How to Solve
Remarks
1
If the temperature sensor on
outdoor power source board is in
good contact with the slot (CN1,
CN2)
Insert again if loose.
Photo 3
2
Measure the resistance on the two ends of
outdoor temperature sensor:
Resistance of CN1 terminal sensor –
(25 / 5K
Ω
). For other resistance, please
℃
refer to the Temperature – Resistance
Sheet. Resistance of CN2 terminal sensor
– (25 / 20K
Ω
). For other resistance,
℃
please refer to the Exhaust Temperature
Sensor Resistance Sheet.
Replace the temperature sensor
if the resistance is incurred to
drift, open or short circuiting.
Photo 4
3
If the above testing is normal
Outdoor power source board
Position and marking of
temperature sensors (CN1, CN2) on
outdoor power source board
CN1 terminal sensor
CN2 terminal sensor