54
DEH-P720,P7200
(4) Display of Operational Status (CPOINT) during Setup
Status No. Contents
Protective action
00
CD
+
5V ON process in progress.
None
01
Servo LSI initialization (1/3) in progress.
None
02
Servo LSI CRAM initialization in progress.
None
03
Servo LSI initialization (2/3) in progress.
None
04
Offset adjustment (1/3) in progress.
None
05
Offset adjustment (2/3) in progress.
None
06
Offset adjustment (3/3) in progress.
None
07
FZD adjustment in progress.
None
08
Servo LSI initialization (3/3) in progress.
None
10
Carriage move to home position started.
None
11
Carriage move to home position started.
None
12
Carriage is moving toward inner diameter.
Specified 10 seconds has been passed or failure
on home switch.
13
Carriage is moving toward outer diameter.
Specified 10 seconds has been passed or failure
on home switch.
14
Carriage outer kick in progress.
None
15
Carriage outer diameter feed (1 second) in progress.
None
20
Servo close started.
None
21
Pre-processing for focus search started.
None
22
Spindle rotation and focus search started.
None
23
Waiting for focus close (XSI
=
Low).
Specified focus search time has been passed.
24
Standing by after focus close is over.
Specified focus search time has been passed.
25
Focus search preprocessing is in
None
progress while setup protection is turned on.
26
Focus search preprocessing is in
None
progress while focus recovery is turned on.
27
Wait time after focus close is set up.
Off focus.
28
Standing by after focus close is over.
Off focus.
29
Setup (1/2) before T balance adjustment is started.
Off focus.
30
Setup (2/2) before T balance adjustment is started.
Off focus.
31
T balance adjustment started.
Off focus.
32
T balance adjustment (1/2).
Off focus.
33
T balance adjustment (2/2).
Off focus.
34
Waiting for spindle rotation to end.
Off focus.
Spindle rough servo.
35
Standing by after spindle rough servo is over.
Off focus.
36
RF AGC started.
Off focus.
37
RF AGC started.
Off focus.
38
RF AGC ending process in progress.
Off focus.
39
Tracking close in progress.
Off focus.
40
Standing by after tracking is closed.
Off focus.
Carriage closing in progress.
41
Focus/tracking AGC started.
Off focus.
42
Focus AGC started.
Off focus.
43
Focus AGC in progress.
Off focus.
44
Tracking AGC in progress.
Off focus.
45
Standing by after focus/tracking AGC are over.
Off focus.
46
Spindle processes applicable servo.
Off focus.
47
Check for servo close is started.
Off focus.
48
Check of LOCK pin started.
Off focus or spindle not locked.
49
RF AGC started.
Off focus.
50
RF AGC in progress.
Off focus.
51
Standing by after RF AGC is over.
Off focus.
Summary of Contents for Suepr Tuner III DEH-P7200
Page 4: ...4 DEH P720 P7200 2 2 EXTERIOR ...
Page 7: ...7 DEH P720 P7200 ...
Page 8: ...8 DEH P720 P7200 2 3 CD MECHANISM MODULE ...
Page 19: ...19 DEH P720 P7200 5 6 7 8 5 6 7 8 D C B A B KV1410 23 ...
Page 20: ...OEL TEXT 20 DEH P720 P7200 1 2 3 4 1 2 3 4 D C B A 3 4 KEYBOARD UNIT C F CN903 ...
Page 30: ...30 DEH P720 P7200 1 2 3 4 1 2 3 4 D C B A A A TUNER AMP UNIT E E E E E E IC Q ...
Page 31: ...31 DEH P720 P7200 5 6 7 8 5 6 7 8 D C B A A SIDE B E E E E E ...
Page 32: ...32 DEH P720 P7200 1 2 3 4 1 2 3 4 D C B A 4 2 FM AM TUNER UNIT B SIDE A B FM AM TUNER UNIT A ...
Page 33: ...33 DEH P720 P7200 1 2 3 4 1 2 3 4 D C B A B SIDE B B FM AM TUNER UNIT ...
Page 37: ...37 DEH P720 P7200 1 2 3 4 1 2 3 4 D C B A SIDE B D CLAMP CONTROL UNIT D ...
Page 50: ...50 DEH P720 P7200 Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...