55
PDR-F10
[Procedure]
1. Press the CX key and shift to the MPP Offset Readjustment.
(Press the AUTO SPACE key several times to appear the right indication.)
2. Monitor the TE waveform with VC.
Be careful with monitoring TE waveform instead of MPP waveform in the readjustment !
3. Adjust the SCAN key so that TE offset becomes zero.
4. Press the SEARCH key to register the adjustment.
6.6.8 MPP Offset Readjustment
0 mV
±
50 mV
CN102-pin 5 (Tracking err)
Test Point
Adjustment Value
Optimizing DC offset voltage of tracking-error output circuit.
Playback does not function, incapable of searching, or track jumping.
Purpose
Symptom when Out of Adjustment
Adjustment method
FL Indication
CN102
TE
VC
5
6
10: 1 prove
Oscilloscope