PDP-504PU
51
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Command description
Command
Function
GAJ
Obtaining various adjustment values
GPD
Obtaining power-down-point log
GPW
Obtaining panel white-balance adjustment values
GS1
Obtaining information on the unit, such as the software version
GS2
Obtaining information on the status of the unit
GSD
Obtaining information on shutdown
GAJ: Obtaining data on ABL setting values, electronic-control adjustment values, and drive-system adjustment values
GPD: Obtaining power-down-point log on the panel
Note: Ignore the 2-byte checksum at the end.
Order
Data
Size
Remarks
1
ABL table currently used
3 bytes
AB1 - AB3
2
Upper limit of power
3 bytes
000 - 255
3
Vsus adjustment value
3 bytes
000 - 255
4
Vofs adjustment value
3 bytes
000 - 255
5
X-SUS-U1 adjustment value (XU1)
3 bytes
000 - 255
6
X-SUS-U2 adjustment value (XU2)
3 bytes
000 - 255
7
X-SUS-D2 adjustment value (XD2)
3 bytes
000 - 255
8
X-SUS-D1 adjustment value (XD1)
3 bytes
000 - 255
9
Y-SUS-U1 adjustment value (YU1)
3 bytes
000 - 255
10
Y-SUS-U2 adjustment value (YU2)
3 bytes
000 - 255
11
Y-SUS-D1-2 adjustment value (YD2)
3 bytes
000 - 255
12
Y-SUS-D1-1 adjustment value (YD1)
3 bytes
000 - 255
13
Y-SUS-D2-2 adjustment value (YD4)
3 bytes
000 - 255
14
Y-SUS-D2-1 adjustment value (YD3)
3 bytes
000 - 255
Order
Data
Size
Remarks
1
Latest "1st PD" data
1 byte
0-C or F
2
Latest "2nd PD" data
1 byte
0-C or F
3
Data of hour meter for the latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
4
Data on temperature for the latest PD (TEMP1)
3 bytes
000 - 255
5
Second latest "1st PD" data
1 byte
0-C or F
6
Second latest "2nd PD" data
1 byte
0-C or F
7
Data of hour meter for the second latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
8
Data on temperature for the second latest PD (TEMP1)
3 bytes
000 - 255
9
Third latest "1st PD" data
1 byte
0-C or F
10
Third latest "2nd PD" data
1 byte
0-C or F
11
Data of hour meter for the third latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
12
Data on temperature for the third latest PD (TEMP1)
3 bytes
000 - 255
13
Fourth latest "1st PD" data
1 byte
0-C or F
14
Fourth latest "2nd PD" data
1 byte
0-C or F
15
Data of hour meter for the fourth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
16
Data on temperature for the fourth latest PD (TEMP1)
3 bytes
000 - 255
17
Fifth latest "1st PD" data
1 byte
0-C or F
18
Fifth latest "2nd PD" data
1 byte
0-C or F
19
Data of hour meter for the fifth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
20
Data on temperature for the fifth latest PD (TEMP1)
3 bytes
000 - 255
21
Sixth latest "1st PD" data
1 byte
0-C or F
22
Sixth latest "2nd PD" data
1 byte
0-C or F
23
Data of hour meter for the sixth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
24
Data on temperature for the sixth latest PD (TEMP1)
3 bytes
000 - 255
25
Seventh latest "1st PD" data
1 byte
0-C or F
26
Seventh latest "2nd PD" data
1 byte
0-C or F
27
Data of hour meter for the seventh latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
28
Data on temperature for the seventh latest PD (TEMP1)
3 bytes
000 - 255
29
Eighth latest "1st PD" data
1 byte
0-C or F
30
Eighth latest "2nd PD" data
1 byte
0-C or F
31
Data of hour meter for the eighth latest PD
7 bytes
1st-5th byte: Hour, 6th-7th byte: Minute
31
Data on temperature for the eighth latest PD (TEMP1)
3 bytes
000 - 255
Notes: • Ignore the 2-byte checksum at the end. • For details, see "Description on power-down."