• RS-232C Commands for the module microcomputer
Command Name
Function
Validity of direct numeric input
Validity
Lower limit Upper limit
1
ABL
ABL ADJUSTMENT
Adjusting the upper limit of the power
?
0000
255
2
AMN
AUDIO MUTE NO
Turning off the audio muting
3
AMY
AUDIO MUTE YES
Turning on the audio muting
4
BAL
BALANCE ADJUSTMENT
Adjusting the audio balance
?
98
158
5
BAS
BASS ADJUSTMENT
Adjusting the audio bass
?
121
135
6
BCP
BACKUP COPY
Copying the backup data in the EEPROM
7
CTM
CLEAR TRAP MEMORY
Clearing the TRAP log that records detection of opening of the rear cover
8
DRF
DRIVE OFF
Driving off
9
DRN
DRIVE ON
Driving on
10
F50
FREQENCY VIDEO 50Hz
Setting the frequency in Mask mode to 50 Hz (VIDEO)
11
F60
FREQENCY VIDEO 60Hz
Setting the frequency in Mask mode to 60 Hz (VIDEO)
12
F61
FREQENCY PC 60Hz
Setting the frequency in Mask mode to 60 Hz (PC)
13
F70
FREQENCY PC 70Hz
Setting the frequency in Mask mode to 70 Hz (PC)
14
F72
FREQENCY VIDEO 72Hz
Setting the frequency in Mask mode to 72 Hz (VIDEO)
15
F75
FREQENCY VIDEO 75Hz
Setting the frequency in Mask mode to 75 Hz (VIDEO)
16
FAJ
FINISH ADJUSTMENT
Z-number F003 to 0003
17
FCN
FOCUS NO
Turning the FOCUS function off
18
FCY
FOCUS YES
Turning the FOCUS function on
19
GAJ
GET ADJUSTMENT
Obtaining various adjustment values
20
GPD
GET POWER-DOWN
Obtaining the power-down-point log
21
GPW GET PANEL WHITE BALANCE Obtaining the panel white-balance adjustment values
22
GS1
GET STATUS 1
Obtaining information on the unit, such as the software version
23
GS2
GET STATUS 2
Obtaining information on the status of the unit, such as the temperature
24
GSD
GET SHUT DOWN
Obtaining information on shutdown
25
LNN
LOUDNESS NO
Turning the Loudness function off
26
LNY
LOUDNESS YES
Turning the Loudness function on
27
M00
MASK MODE 0
Turning the Mask function off
28
M01
MASK MODE 1
White raster (change in luminance level)
29
M02
MASK MODE 2
White raster--zigzag, exact reverse--scan--gray--white raster
30
M03
MASK MODE 3
White raster--zigzag, exact reverse--scan--gray--white raster
31
M10
MASK MODE 10
H ramp (slant 1)
32
M11
MASK MODE 11
H ramp (slant 4)
33
M12
MASK MODE 12
H ramp (slant 1 shifting)
34
M13
MASK MODE 13
H ramp (slant 4 shifting)
35
M14
MASK MODE 14
V ramp (slant 1)
36
M15
MASK MODE 15
Slanting ramp
37
M20
MASK MODE 20
Window (for WB adjustment, Hi = 870, Lo = 102)
38
M21
MASK MODE 21
Window (for WB adjustment, Hi = 1023, Lo = 102)
39
M22
MASK MODE 22
Window (for measuring the peak luminance during WB adjustment, Hi = 1023)
40
M23
MASK MODE 23
Window (for measuring the peak luminance, Hi = 1023, 4%)
41
M24
MASK MODE 24
Window (for measuring the peak luminance, Hi = 1023, 1.25%)
42
M25
MASK MODE 25
Window (vertical line with 1/7-width for measuring the stress)
43
M26
MASK MODE 26
Window (magenta, green, and stripe for check)
44
M27
MASK MODE 27
Window (green,magenta, and stripe for checker)
45
M28
MASK MODE 28
Window (black & white [1 x 8], checker, for EMG check)
46
M29
MASK MODE 29
Window (for WB adjustment, magenta = 512, yellow = 512)
47
M2E
MASK MODE 2E
Wiper for erasing afterimage
48
M2F
MASK MODE 2F
Mask for warning of cable disconnection
49
M30
MASK MODE 30
ColorBar
50
M31
MASK MODE 31
Slanted lines (for checking cable disconnection)
51
M51
MASK MODE 51
Raster-white
52
M52
MASK MODE 52
Raster-red
53
M53
MASK MODE 53
Raster-green
54
M54
MASK MODE 54
Raster-blue
55
M55
MASK MODE 55
Raster-black
56
M56
MASK MODE 56
Raster-cyan 1023
57
M57
MASK MODE 57
Raster-magenta 1023
58
M58
MASK MODE 58
Raster-yellow 1023
59
M59
MASK MODE 59
Raster-cyan 274
60
M60
MASK MODE 60
Raster-flesh color_50
61
M61
MASK MODE 61
Raster-light purple_50
62
M62
MASK MODE 62
Raster-sky blue_50
63
M63
MASK MODE 63
Raster-red 779
64
M64
MASK MODE 64
Raster-cyan 218
65
M65
MASK MODE 65
Raster-cyan 448