9.3 OUTLINE OF EACH COMMANDS
9.3.1 ACQUISITION OF PANEL STATUS • • • [QS1]
Model information and version information are returned.
Command
Format
Effective Operation
Modes
Function
Remarks
[QS1]
Every Time
Output of status
Return data: 105 Byte
1: Resolution/Inch size
3
1024
∗
768/42
4
1024
∗
768/43
5
1280
∗
768/50
6
1365
∗
768/50
7
1365
∗
768/60
F
1920
∗
1080/50
2: Panel Generation
6
G6
7
G7
8
G8
9
G9
0
G10
3: Destination
∗
Commonness
A
US (Reserved)
E
EU (Reserved)
J
Japan (Reserved)
12: Panel Type
P
The past
F
High-effiective
4: System Type
∗
Commonness
Z
Evaluation
Data Arrangement
Data
Length
Output Example
ECO
3 byte
QS1 (Fixed)
1
Display information 1 (Resolution/inch size)
1 byte
F
2
Display information 2 (Panel Generation)
1 byte
7: G7
3
Display information 3 (Destination)
1 byte
A: USA
4
Display information 4 (System Type)
1 byte
∗
5
Display information 5 (Panel Product Form)
1 byte
B
6
MDUcom-Boot
3 byte
01A
7
MDUcom-Prg
8 byte
8
Seq Prs-Boot
3 byte
01A
9
Seq Prs-Prg
8 byte
10
SQ-VIDEO
4 byte
11
SQ-PC
4 byte
12
Panel Type
1 byte
P/F
13
Reserved (
∗
)
7 byte
∗∗∗∗∗∗∗
14
, (comma)
1 byte
15
MTB information 1 (Generation)
1 byte
7: G7
16
MTB information 2 (Regional model)
1 byte
A: USA
17
MTB information 3 (Grade)
1 byte
H: Elite
18
MTB information 4 (System Type)
1 byte
B
19
Common version for IF microcomputer
4 byte
20
Common version for Main microcomputer
8 byte
21
Boot version of Main microcomputer
4 byte
22
Common version for Multi-processor
8 byte
23
Boot version of Multi-processor
4 byte
24
Reserved (
∗
)
Check Sum
24 byte
25
2 byte
FF
5: Panel Product Form
S
System model
B
All-in-one design TV
M
Monitor
D
Standard module
E
Simple module
15: MTB/MB Generation
6
G6
7
G7
8
G8
9
G9
0
G10
16: Regional Model
J
JP
A
US
E
EU
G
GE
C
CH
U
AU
17: MTB/MB Grade
H
Elite/DXA/Step-upD
T
Step-upA/XG/TXC/Regular (US)
B
Not used (For Future)
18: MTB/MB Product Form
S
System model
B
One body model (SX)
M
Monitor (FHD)
S
RegularD
R
RegularA
19 to 23: MTB/MB-side's information
IF uCON
Common version of IF microcomputer
Main uCON
Common version of Main microcomputer
Main uCON-Boot
Boot version of Main microcomputer
Multi-prs
Common version of Multi-processor
program
Multi Prs-Boot
Boot version of Multi-processor program