MJ-D508
49
7. GENERAL INFORMATION
7.1.1 TROUBLESHOOTING
7.1 DIAGNOSIS
7
The power of the system does not turn to ON. Display does not light up.
Detal of Display
is normal ?
OK
Display
lights UP ?
Check for connection of Transformer to MAIN UNIT ASSY and
connection of DISPLAY UNIT ASSY to MAIN UNIT ASSY.
START
POWER ON
No
Yes
Yes
No
Display is dark
or Display flickers
D202(Zener diode) is short-circuited or open.
" SIO Error "
Message shown
on the display
Refer to "DETAILS OF ERROR DISPLAY" (next page).
¶
Connection of DISPLAY UNIT ASSY to MAIN
UNIT ASSY or Connection of MD MECHANISM
ASSY to MAIN UNIT ASSY is wrong.
¶
IC301(Protector) is open.
¶
IC305(Protector) is open.
¶
IC201(Protector) is open.
¶
Transformer temperrature fuse is open.
¶
IC201(SYSTEM CONTROL
µ
COM) is broken.