A
B
C
D
5
6
7
8
5
6
7
8
2
1
-28
¶
In regard to the voltage at pin 22 of IC5001 (LEVEL IN)
• This terminal monitors the input signal level for operation of the
automatic standby mode.
• When INPUT key (INPUT 2) is selected and -46dB V (about 5mV rms)
is applied as input (input to both channels, freq. =1kHz), this terminal
rises to about 0.8V DC (in case of both channels, -40 dB V, about 0.8V
DC) and POWER ON is effected.