GM-X822,X722
19
6. ADJUSTMENT
No. Item
Conditions
Adjustment point
Specifications
1 Idling current
Input ; adjust 30 seconds after 1k
Ω
terminate
VR101(Lch)
mV Meter(1) : 12mV
±
3mV
(adjustment)
power is switched on, and within 20 seconds.
VR201(Rch)
2 DC-DC converter
Input ; adjust 30 seconds after 1k
Ω
terminate
VR951
mV Meter(2) : 30V
±
3V
voltage
power is switched on, and within 20 seconds.
(adjustment)
-
Connection Diagram
L
1k
Ω
R228
SYSTEM
CONTROL
GND
POWER
VR951
VR201
VR101
mV Meter
(1)
DC Regulated
Power Supply
mV Meter
(1)
E
C
Q213
GND
1k
Ω
R
mV Meter
(2)
AMP UNIT
4
Ω
(2W)
+14.4V
4
Ω
(2W)
SPEAKER
OUTPUT
R128
Fig. 8
Summary of Contents for GM-X722 X1R/ES
Page 3: ...3 GM X822 X722 2 4 3 1 10 7 9 8 5 6 8 11 2 EXPLODED VIEWS AND PARTS LIST 2 1 PACKING Fig 1 ...