44
1
2
3
4
1
2
3
4
F
E
D
C
B
A
GEX-M7027XMZH/XN/UC
Number Mode name Entry method
Summerized Description
Press the number 3 key for less
than two seconds while in XM2
of the Diagnostic mode.
Press the number 4 key for less
than two seconds while in XM2
of the Diagnostic mode.
Press the number 5 key for less
than two seconds while in XM2
of the Diagnostic mode.
Press the number 1 key for more
than two seconds while in XM2
of the Diagnostic mode.
Press the number 2 key for more
than two seconds while in XM2
of the Diagnostic mode.
Press the number 3 key for more
than two seconds while in XM2
of the Diagnostic mode.
Press the number 4 key for more
than two seconds while in XM2
of the Diagnostic mode.
Press the number 6 key for more
than two seconds while in XM2
of the Diagnostic mode.
Decryption LOCK/UNLOCK of satellite wave 1 signal,
decryption rate of Bitabi signal (two effective digits of
decimal value) + RS error correction rate (two effective
digits of decimal value) + RS error rate (two effective
digits of decimal value).
Decryption LOCK/UNLOCK of satellite wave 2 signal,
decryption rate of Bitabi signal (two effective digits of
decimal value) + RS error correction rate (two effective
digits of decimal value) + RS error rate (two effective
digits of decimal value).
Information on LOCK/UNLOCK of PLL and connection
information of terrestrial wave and satellite wave
antennas.
PC reception synchronization/asynchroni
overflow count during voice service data input +
underflow count during PCM output.
General error codes for SSDEC (six effective digits of
hexadecimal value).
SSDEC service extraction error code 1 (four effective
digits of hexadecimal value).
SSDEC service extraction error code 2 (four effective
digits of hexadecimal value).
Major version (three digits of decimal value) + minor
version (one digit decimal value).
15
16
17
18
19
20
21
22
23
24
Unused
Unused
SAT1
Message
SAT2
Message
Tuner
Message
SSDEC
Status 1
SSDEC
Status 2
SSDEC
Status 3
SSDEC
Status 4
MICRO
VERSION
4. Details of the Diagnostic mode
4.1 BERINFO
Display format: [(1)(2) (3) (4)(5) (6) (7)(8)].
(1) The Bitabi signal decryption error rate (effective value) for satellite wave 1*.
(2) The Bitabi signal decryption error rate (truncated binary exponential, with negative sign abbreviated) for
satellite wave 1*.
(3) Spacing character.
(4) The Bitabi signal decryption error rate (effective value) for satellite wave 2*.
(5) The Bitabi signal decryption error rate (truncated binary exponential, with negative sign abbreviated) for
satellite wave 2*.
(6) Spacing character.
(7) The Bitabi signal decryption error rate (effective value) for terrestrial waves*.
(8) The Bitabi signal decryption error rate (truncated binary exponential, with negative sign abbreviated) for
terrestrial waves*.
* Each piece of information is effective following the initialization of CDEC. The updating interval is 432 ms. If not
any of the modulated wave signals can be received (that is, the signal cannot be LOCKed), then a hyphen ("-") will
be displayed.
"If notany of the modulated wave signals can be received" it represents a condition that the modulated signals
could not receive the signals described in section 4.2.
Display example: If the satellite wave 1 = 10%, satellite wave 2 = 3.4% and terrestrial wave = 0.23%, the display will
show [11_32_23].
Summary of Contents for GEX-M7027XMZH
Page 17: ...B b B A CN501 17 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 19: ...A a B b B a B a B b 3 4 19 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 20: ...B a B b B b 1 2 20 1 2 3 4 1 2 3 4 F E D C B A GEX M7027XMZH XN UC ...
Page 21: ...B a B b B b 3 4 A CN501 CN2 21 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 23: ...C b C SSDEC CAP DAC C DIGITAL UNIT 23 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 24: ...A a C b C a C a C b 1 2 3 SDRAM 24 1 2 3 4 1 2 3 4 F E D C B A GEX M7027XMZH XN UC ...
Page 25: ...A a C b C a C a C b 4 CDEC A CN502 25 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 27: ...C a C b C b 4 SSDEC CAP 27 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 29: ...29 A SIDE A C CN201 B CN2 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 30: ...30 A A MAIN UNIT 1 2 3 4 1 2 3 4 F E D C B A GEX M7027XMZH XN UC ...
Page 31: ...31 A SIDE B 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 33: ...B B RF UNIT SIDE B IC Q A CN501 33 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...
Page 35: ...35 C C DIGITAL UNIT SIDE B IC Q A CN502 5 6 7 8 F E D C B A 5 6 7 8 GEX M7027XMZH XN UC ...