6.3 ERROR MODE
7
Error codes
In the case where the CD is disabled or stopped by error during operation, the mechanism enters the error
mode. The causes of errors are given with numbers.
7
Error code displaying method
Error codes for the mechanical module consist of four digit numbers. They are displayed by carrying out a
specific operation (command) for the product.
The upper two digits indicate the major category and description of an error. The lower two digits indicate the
detailed status of internal parts of the mechanism on occurrence of an error.
7
G3 electric system error display
Power system error
7
G3 servo-system error display
Servo-system error
7 7 7 7
(
7
represents a number.)
Internal status of the mechanism on occurrence of an error
(lower two digits)
Error description
(upper two digits)
Code
0xA0
0xA1
Error
VD power fault
Mechanism reference voltage fault
Error description, upper (1 and 2 digits)
VDSENS error
CAMREF or ELVREF error
Code
0x10
0x11
0x12
0x17
0x22
0x23
0x30
Error
Carriage home fault
Focus search fault
Spindle lock or sub-code fault
Setup fault
Play is disabled
(at the time of playing compressed audio)
File format fault (for compressed audio)
Error description, upper (1 and 2 digits)
Carriage does not move to inner radius.
Carriage does not move out of the inner radius. Switch fault
Correct focus is not obtained.
Spindle is not locked.
Sub-code cannot be read.
AGC protection is disabled.
Easy to be out of focus.
MP3 file that can be played does not exist.
The audio data is written in a file format
which is not supported by the mechanism.
The target address cannot be reached
0x55
0x56
0x57
0x58
0x59
0x5a
0x5b
TRYDN
CRGIN
Error description, upper (1 and 2 digits)
Forward direction timeout at the time of mechanical operation given in the left column
Reverse direction timeout at the time of mechanical operation given in the left column
Overrun/under run at the time of mechanical operation given in the left column
Failed to access because of pulse drive at the time of mechanical operation given in the left column.
Forward direction timeout at the time of mechanical operation given in the left column
Reverse direction timeout at the time of mechanical operation given in the left column
Overrun at the time of mechanical operation given in the left column
Failed to access because of pulse drive at the time of mechanical operation given in the left column.
Forward direction timeout at the time of mechanical operation given in the left column
Reverse direction timeout at the time of mechanical operation given in the left column
Overrun/under run at the time of mechanical operation given in the left column
Failed to access because of pulse drive at the time of mechanical operation given in the left column.