When stopping of the fan is detected
Flashes 3 times.
Error indications when an abnormality in the amplifier system is detected
[Purpose]
[Error Messages]
FL Display
When a thermal shutdown (abnormal
temperature), etc. is detected
When AMP DC is detected
Flashes 3 times.
Flashes 3 times.
Status
Duration
(sec.)
An error message is displayed when an abnormality in the amplifier system is detected.
After a failure is detected, the shutdown process starts,
then the power will be off. The power can be turned on
again in Normal mode.
AMP ERROR
: After a failure in the amplifier block or high DC output is detected, the shutdown process starts, then
the power will be shut off. Then the MCACC LED will flash. The power cannot be turned on again.
If you wish to turn on the unit after a shutdown activated by DC detection, enter Test mode, by
proceeding with the steps described in "How to enter release mode" below.
FAN STOP
: The fan does not function.
OVERHEAT
: The temperature of the amplifier is
abnormally high.
12V TRG ERR : The 12-V trigger output is short-circuited.
(KUXJ and KUXJCA types only)
XM ANT ERR
: Thepower supply of the XM antenna is
abnormally.
(KUXJ and KUXJCA types only)
[Description]
[How to enter release mode]
Press and hold DVR/VCR2 and ENTER keys
on the front panel simultaneously for 5 seconds in standby mode.
When the 12-V trigger circuit is
short-circuited
Flashes
80TXV types only
KUXJ and KUXJCA types only
The power supply of the XM antenna
is abnormally
Flashes