34
SC-71
1
2
3
4
A
B
C
D
E
F
1
2
3
4
5.2 CIRCUIT DESCRIPTION
[1] Protection Circuit Process List
Amplifier Circuit
Item
Purpose
Detection Method
Status of Equipment Warning Indication
Remarks
Overheat
detection
Detects MOS FET
temperature of amplifier output
stage
Detects when TEMPERR5 PORT
becomes "L" in case of the
detecting temperature exceeds
95°C or rapid change by short
cuicuit of speaker terminals.
(IC6111 24pin)
Blinks FL OFF LED
indicator.
Recoverable by power-on
after shutdown in one
minute.
DC
detection
Detects DC of amplifier output
(After LPF)
Detects when SP output exceeds
and XDCERR port
becomes "L". (IC6111 21pin)
MUTE on and Speaker
Relay off.
Flashes “AMP ERR”.
Shuts down when
abnormality continues for
more than 3 seconds.
MUTE on and Speaker
Relay off.
Flashes “AMP ERR”.
Shuts down when
abnormality continues for
more than 3 seconds.
Blinks ADVANCED
MCACC LED
Blinks FL OFF LED
indicator.
In case of detecting DC
abnormality during normal
operation. Recoverable by
power-on after 1 minute.
In case of detecting DC
abnormality during
power-on sequence after
the DC was once detected.
Recoverable by only DC
DETECT cancel.
Refer to “How to Enter
Release Mode” .
Blinks iPod iPhone iPad
LED
Blinks iPod iPhone iPad
LED
Recoverable by power-on
Recoverable by power-on
Zobel
detection
Protects overcurrent by Zobel
Resistance when high power
output of higher frequency
continued
Detects XOLERR port becomes "L".
(IC6111 13pin)
Shuts down
Shuts down
Shuts down
Overcurrent
detection
Protects overcurrent of MOS
FET in output stage when
overcurrent flows at the output
stage
Detects XOLERR port becomes "L".
(IC6111 13pin)
During Standby mode, simultaneously press and hold the "TUNE [ ] " and "ZONE2 ON/OFF" keys for 5 seconds.
[How to Enter Release Mode]
Flashes "OVERHEAT"
Shuts down when
abnormality continues for
more than 3 seconds.
Detects abnormal in the
Amplifier Power Supply
Blinks ADVANCED
MCACC LED
Recoverable by only DC
DETECT cancel.
Refer to “How to Enter
Release Mode” .
Amplifier
Power
Supply
failure
detection
Detects B-Power Supply Voltage
exceeds
falls below
and XBERR port becomes "L".
(IC6111 23pin)