• Identification of locations having abnormality by the number of times the LEDs flash
On Shutdown and power-down
∗
If the unit cannot identify which protection circuit was activated, even if a power-down had been detected, the red LED may flash 15 times.
Shutdown
• Operation: When the microcomputer detects any abnormality, it forcibly turns off the unit.
• LED indication: The green LED flashes.
Power-down
• Operation: When the unit is in emergency status, a protection circuit is activated, and the power is turned off.
• LED indication: The red LED flashes.
Category
MR-LED
PANEL-LED
Content
Unit's operation
Warning indication
when the MR is connected
STB
ON
STB
ON
SD
Lit
1 time
Communication failure of the
panel-drive IC
Immediate shutdown
Lit
2 times
Communication failure of the
module IIC
Immediate shutdown
Lit
3 times
Power decrease of the digital
DC-DC converter
Immediate shutdown
Lit
4 times
Panel having high
temperature
Shutdown 30 seconds
after warning
Powering off. Internal temperature too high
Check temperature around PDP.
Check temperature around media receiver.
[SD04]
Powering off. Internal temperature too high
Check temperature around PDP.
Check temperature around media receiver.
[SD11]
Lit
5 times
Audio failure
Shutdown 3 seconds
after warning
Powering off.
Internal protection circuits activated,
Is there a short in speaker cable ?
[SD05]
6 times
Lit
Communication failure of the
module microcomputer
Immediate shutdown
7 times
Lit
Main 3-wire serial
communication in failure
Immediate shutdown
8 times
Lit
Communication failure of the
main IIC
Immediate shutdown
9 times
Lit
Communication failure of the
main microcomputer
Immediate shutdown
10 times
Lit
Fan in failure
Immediate shutdown
11 times
Lit
MR or unit having higher
temperature
Shutdown 30 seconds
after warning
12 times
Lit
Communication failure of the
digital tuner
Immediate shutdown
13 times
Lit
MR-ASIC power (DC-DC) in
failure
Immediate shutdown
14 times
Lit
Communication failure of
IF-EEPROM
Immediate shutdown
PD
1 time
Lit
MR power supply
Immediate power-down
Lit
2 times
Panel-POWER SUPPLY
Immediate power-down
Lit
3 times
SCAN
Immediate power-down
Lit
4 times
SCAN-5V
Immediate power-down
Lit
5 times
Y-DRIVE
Immediate power-down
Lit
6 times
Y-DCDC
Immediate power-down
Lit
7 times
Y-SUS
Immediate power-down
Lit
8 times
ADDRESS
Immediate power-down
Lit
9 times
X-DRIVE
Immediate power-down
Lit
10 times
X-DCDC
Immediate power-down
Lit
11 times
X-SUS
Immediate power-down
Lit
12 times
DIGITAL-DCDC
Immediate power-down
Lit
15 times
UNKNOWN
∗
Immediate power-down
45
PDP434PU, PDP504PU, PRO434PU, PRO504PU, PDP435PU, PDP505PU, PRO435PU, PRO505PU
Summary of Contents for Elite PRO-506PU
Page 2: ......
Page 8: ... 2 4 SI PG06003 A Warranty Claim Example 8 ...
Page 14: ...14 Quick Reference G 3 to G 8 Power Down Shut Down Trap Switch Reset Service Remotes ...
Page 23: ...23 Models PDP433PU PDP503PU Block Diagrams Shut Down Power Down Diagnosis ...
Page 30: ...30 Models PDP433CMX PDP503CMX PDP4300 PRO800HD HDI PRO1000HD HDI ...
Page 31: ...31 Block Diagrams Basic Service Factory Mode Shut Down Power Down Diagnosis ...
Page 48: ...48 Models PDP434CMX PDP504CMX PDP505CMX PDP4304 PDP4314 PDP5004 PDP5014 PRO810HD PRO1010HD ...
Page 49: ...49 Block Diagrams Operation LED Statuses Power Down Shut Down Diagnosis ...
Page 72: ...72 Models PDP436PU PDP506PU PRO436PU PRO506PU ...
Page 73: ...73 Block Diagrams Operation LED Statuses Shut Down Power Down Diagnosis System Reset ...
Page 82: ...82 Models PDP4270HD PDP4271HD PDP5070HD PDP5071HD PDP6070HD PDP6071HD PRO507PU PRO607PU ...
Page 87: ...87 Models PDP6070HD PDP6071HD PRO607PU Block Diagrams on the next two pages ...
Page 120: ...120 Scan IC Troubleshooting Blue Glue Removal IC Removal ...
Page 121: ......
Page 142: ...142 ...