PD-D6-J
68
1
2
3
4
1
2
3
4
C
D
F
A
B
E
7.1.4 SEQUENCE AFTER POWER ON/OFF
Set time for the current step
Elapsed time
Details on control
0 msec
POWER ON start, Various initial settings
1
All keys are masked.
XSYSMUTE ON
+ 60 msec
60 msec
Various initial settings
2
SYSPOW ON
When the power is turned on, the HELLO display is requested (3.5 sec).
+ 240 msec
300 msec
Various initial settings
3
RESET L
⇒
H
+ 60 msec
360 msec
Various initial settings
4
Control of the LCD driver starts.
Data transmission
+ 1020 msec
1380 msec
Various initial settings
4
Bus communication starts.
+ 390 msec
1770 msec
Various initial settings
5
+ 120 msec
1890 msec
Various initial settings
6
Masking of all keys is canceled.
+ 3120 msec
5010 msec
Various initial settings
7
Temporary data transmission
+ 30 msec
5040 msec
POWER ON completed
Normal POWER-ON sequences
Normal POWER-OFF sequences
Set time for the current step
Elapsed time
Details on control
0 msec
POWER OFF start, Various settings
1
The mask flags for all keys are set.
+ 30 msec
30 msec
(Note 1)
Various settings
2
Whether the DVD is turned off or not is checked.
Bus communication is terminated.
+ 120 msec
150 msec
Various settings
3
+ 330 msec
480 msec
Various settings
4
+ 1320 msec
1800 msec
Various settings
4
All the indications on the LCD are deleted.
+ 90 msec
1890 msec
Various settings
5
+ 240 msec
2130 msec
Processing for the ports required when the power is turned off
+ 30 msec
2160 msec
POWER OFF completed
(passes every loop in the POWER OFF)
Note 1: In this step, the unit wait for the DVD module to turn the power off. If the DVD module takes a longer time to turn itself off,
the elapsed time will become longer, by just that much.