Table 3: List of Key Codes
How to enter each check mode
Test mode remote control unit : [A8**]
Remote control unit supplied with the DVR : [AB**]
No.
Check Item
Key Input
Operation / purpose
Remarks
1
EE system
(same as preview)
[ESC]
→
[A.MON]
Turns on/off EE mode cyclically
Make sure that CGMS = 11 becomes when
CGMS = 10 is input.
EE mode: Simulation mode for recording status
[PLAY]
Starts the EE system in EE mode
(main-unit setting rate)
[STOP]
Stops the EE system in EE mode
2
Error-rate measurement
[ESC]
→
[SIDEB]
V-mode recording:
After recording for 10 seconds, the
unit starts playback while
displaying the error rate.
DVD-Video:
The error rate is automatically
measured, then the result will be
displayed.
For details, see
" 7.1.4 ERROR RATE MEASUREMENT ".
3
Settings for specific areas
[ESC]
→
[CHP/TIM]
Enters Adjustment mode for AVIO
settings
Settings are made for the selected input
(TUNER, LINE).
For details, see
" 7.1.5 SETTINGS FOR SPECIFIC AREAS ".
[ESC]
Determines the settings, then exits
Adjustment mode
How the ESC code is processed
• When the ESC code is received, ESCAPE mode is entered, but in combination with the code(s) that follow(s), a specific meaning is added.
• If ESC codes are received continuously, ESCAPE mode is retained.
40