DVD-R7783
43
5
6
7
8
5
6
7
8
C
D
F
A
B
E
7. GENERAL INFORMATION
7.1 DIAGNOSIS
7.1.1 OPERATIONAL DIAGNOSIS PROGRAM
Diagnose5 is application software for operation diagnoses
of Pioneer DVD changers for use with 100, 500, and 700
DVDs. Diagnosable functions are disc movement, the read
function, and the write function. Rewriting of the serial
number, acquisition of internal information, and upgrading
of the firmware are also possible. When "diagnoses of all
drives" is executed, diagnoses of disc movement and the
read function, and acquisition of internal information are
executed, in that order, and the results are recorded in a
log.
Diagnose5 supports one SCSI bus and one changer. It
must be used in an environment where no device other
than a changer and the drives in it is connected on the
SCSI bus.
Supported OS:
Windows NT4.0/95/98/Me/2000
Note:
The ATAPI drive is not supported.
Main screen (when no changer is connected)
Select button
When this button is clicked on, the diagnosis menu
corresponding to the drive selected in the list box is
displayed.
Note:
The ATAPI drive name is displayed on the screen,
depending on the version of the ASPI manager, but
the ATAPI drive is not supported.
Diagnosis button
Selected diagnosis items are executed. If an error occurs,
error content will be displayed in the list box, and the
diagnosis in progress will be stopped. The results of
diagnosis and error content will be displayed on the screen,
and they are also recorded in a file "driven.log" that is
created for each drive, where n is the drive number.
Update button
(useable only when no changer is connected)
To update disc data for the loaded disc. Click on this button
after a disc is loaded or unloaded manually.
Designating address READ
All-address error rate
Data-transfer rate
1. Items required for operation checks
Connections when operations of the DVD-R7783
alone are checked
• GGS1030: Operation check program
(Diagnose5.exe, chgpio32.dll, cdiagp32.dll)
• GGP1061: Connector Assy (LVD)
• GGP1062: SCSI cable (LVD)
• GGP1063: SCSI terminator (LVD)
• GGF1485: Special device for RS-232C communication
for the changer drive
(used for short-circuiting XCLMP)
PC
DVD-R7783
GGP1062
SCSI cable (LVD)
GGP1061
Connector Assy (LVD)
GGP1063
SCSI terminator (LVD)
GGF1485
Used for short-circuiting
between XCLMP and GND
2. Outline
4. How to use
5. Diagnosis (READ)
Diagnose5 is composed of one executable file
(Diagnose5.exe) and two dll files (chgpio32.dll and
cdiagp32.dll). With Windows NT, it is necessary to install
the ASPI manager (wnaspi32.dll) beforehand. For
installation, copy an executable file (version 2.900 or later)
and the dll file in the same folder on the PC.
Note:
Set "automatic notification of insertion" for the drive to OFF.
If it is set to ON, the program may not operate properly. If a
drive with this setting set to ON is connected, a message
asking whether to change this setting to OFF is displayed
when Diagnose5 is started up. In such a case, select "Yes"
then restart your PC.
3. Composition of the software