4. How to confirm the version of the firmware
Press the ESC then the CHAP key on the remote control unit for servicing. The version of the firmware is labeled ROM
NUMBER. Check if the version is the latest one.
5. Troubleshooting
1
If updating of the firmware failed
If the main unit was turned off during updating, it cannot initialize and start up again properly. In such a case, replace the
flash ROM on the DVD MT PCB Assy.
2
If updating of the firmware using the disc for updating failed
• Was the disc for updating recognized properly?
Check if the volume label of the disc is PIONEER.
• Is playback of a disc other than the disc for updating possible?