38
1
2
3
4
1
2
3
4
F
E
D
C
B
A
DEH-2237ZF/X1R/UC
6. ADJUSTMENT
6.1 CD ADJUSTMENT
1) Precautions
• This unit uses a single power supply (+5V) for the reg-
ulator. The signal reference potential, therefore, is
connected to VREF(approx. 2.1V) instead of GND.
If VREF and GND are connected to each other by mis-
take during adjustments, not only will it be impossi-
ble to measure the potential correctly, but the servo
will malfunction and a severe shock will be applied to
the pick-up. To avoid this, take special note of the fol-
lowing.
Do not connect the negative probe of the measuring
equipment to VREF and GND together. It is especially
important not to connect the channel 1 negative
probe of the oscilloscope to VREF with the channel 2
negative probe connected to GND.
Since the frame of the measuring instrument is usual-
ly at the same potential as the negative probe, change
the frame of the measuring instrument to floating sta-
tus.
If by accident VREF comes in contact with GND,
immediately switch the regulator or power OFF.
• Always make sure the regulator is OFF when connect-
ing and disconnecting the various filters and wiring
required for measurements.
• Before proceeding to further adjustments and mea-
surements after switching regulator ON, let the player
run for about one minute to allow the circuits to stabi-
lize.
• Since the protective systems in the unit's software are
rendered inoperative in test mode, be very careful to
avoid mechanical and /or electrical shocks to the sys-
tem when making adjustment.
• The RFI and RFO signals are easy to oscillate because
of a wide band. When observing them, insert a resis-
tor of about 1 k
Ω
to the series.
• This equipment will not guarantee the load ejection
operation when the mechanical unit is turned upside
down. In particular, if the ejection operation is incor-
rectly performed and recovery is disabled, the recov-
ery is enabled by resetting a product or turning ACC
off to on.
2) Test Mode
This mode is used for adjusting the CD mechanism
module of the device.
• Test mode starting procedure
Reset while pressing the 4 and 6 keys together.
• Test mode cancellation
Switch ACC, back-up OFF.
• After pressing the EJECT key, do not press any other
key until the disk is completely ejected.
• If the SEEK UP or SEEK DOWN key is pressed while
focus search is in progress, immediately turn the
power off (otherwise the actuator may be damaged
due to adhesion of the lenses).
• Jump operation of TRs other than 100TR continues
after releasing the key. CRG move and 100TR jump
operations are brought into the “Tracking close” sta-
tus when the key is released.
• Powering Off/On resets the jump mode to “Single
TR(91)”, the RF AMP gain setting to 0 dB, and the
automatic adjustment value to the initial value.
Summary of Contents for DEH-2237ZF X1R/UC
Page 5: ...5 6 7 8 F E D C B A 5 6 7 8 DEH 2237ZF X1R UC 5 ...
Page 18: ...18 B A CN604 105mA 8V KL KL 1 2 3 4 1 2 3 4 F E D C B A DEH 2237ZF X1R UC 3 3 KEYBOARD UNIT ...
Page 26: ...26 A A MOTHER UNIT 1 1 2 3 4 1 2 3 4 F E D C B A DEH 2237ZF X1R UC ...
Page 27: ...27 A SIDE B 1 5 6 7 8 F E D C B A 5 6 7 8 DEH 2237ZF X1R UC ...
Page 29: ...B B KEYBOARD UNIT SIDE B A CN604 29 5 6 7 8 F E D C B A 5 6 7 8 DEH 2237ZF X1R UC ...
Page 31: ...31 C C CD CONTROL UNIT SIDE B CLAMP 8EJ 5 6 7 8 F E D C B A 5 6 7 8 DEH 2237ZF X1R UC ...