38
CDX-M2096ZRN
12. To see the amount of dislocation, place the mechanism upside-down.
If the stopper bend has been dislocated in the direction of the first
CD, turn VR802 to the left(Fig. 2).
To lower the stage toward the sixth step by 0.1 mm, reduce the
voltage of EREF (adjusted in step 8) by 20 mV.
If the stopper bend has been dislocated in the direction of the sixth
CD, turn VR802 to the right(Fig. 4).
To raise the stage toward the first step by 0.1 mm, increase the
voltage of EREF (adjusted in step 8) by 20 mV.
13. Place the mechanism horizontal. Go back to step 11 to reconfirm the
stage height.
14. When adjustment of the stage height is completed, proceed as
follows:
15. Press the EJECT switch.
16. Once operation of the mechanism has stopped, turn the power OFF.
17. Wait more than one minute after the power is turned off, then turn the power ON and insert a magazine.
18. Check if the mechanism operates correctly with the first and fourth CDs.
19. If the mechanism operates properly, adjustment is completed. If the mechanism operates improperly, make the
adjustment again.
GND
EREF
VR802
mV meter
Summary of Contents for CDX-M2096ZRN
Page 5: ...5 CDX M2096ZRN 2 2 EXTERIOR ...
Page 7: ...CDX M2096ZRN 2 3 CD MECHANISM MODULE 7 ...
Page 11: ...11 CDX M2096ZRN 3 BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 3 1 BLOCK DIAGRAM A B C D E F G ...
Page 15: ...15 CDX M2096ZRN 5 6 7 8 A B C D 5 6 7 CSS1456 DIG A CN701 B b B 8 ...
Page 16: ...16 CDX M2096ZRN A 1 2 3 4 B C D 1 2 3 4 CCP1338 CCW1021 B B a B a B b ...
Page 17: ...17 CDX M2096ZRN 5 6 7 8 A B C D 5 6 7 8 S851 S852 CSN1033 C F D E B a B a B b C D E F ...
Page 18: ...18 CDX M2096ZRN A 1 2 3 4 B C D 1 2 3 4 CSS1456 DIG B a B b B b ...
Page 19: ...A CN701 19 CDX M2096ZRN 5 6 7 8 A B C D 5 6 7 B b B a B b 8 ...
Page 23: ...23 CDX M2096ZRN ...
Page 25: ...25 CDX M2096ZRN 1 2 3 4 A B C D 1 2 3 4 A EXTENSION PCB A SIDE B ...
Page 27: ...27 CDX M2096ZRN 1 2 3 4 A B C D 1 2 3 4 B SIDE B B CD CORE UNIT ...
Page 35: ...35 CDX M2096ZRN Grating waveform 45 0 75 60 30 90 Ech Xch 20mV div AC Fch Ych 20mV div AC ...