25
5
7
8
F
E
D
C
B
A
5
7
8
AXM-P7050/ES
DISPLAY UNIT BRIGHT ADJUSTMENT
No. Specification
Measuring Point
Adjustment
Note
(Adjustment Item)
Point
1
9.5k
Ω
TP(TP1), TP(TP2)
VR1801
(Digital Multi-meter)
6.3 TEST MODE
• Display test mode
To enter this mode :
Short the land TEST_3 on the pc board, then restart the unit. The pin 86 (TEST_3) of the
IC804 will be shifted to H.
Operations :
Each time you press the 6 button on the remote control, the mode will change cyclically as
follows: No display
→
All OELs light up.
→
Normal display
→
• Test mode
To enter this mode :
Short the land TEST_2 on the pc board, then restart the unit. The pin 80 (TEST_2) of the
IC804 will be shifted to H.
Operations :
When you press buttons on the remote control for each source, the test command will be
sent out.
• Service test mode (only for the AXM-P7050/ES)
Short the land TEST_1 on the pc board, then restart the unit. The pin 62 (TEST_1) of the
IC804 will be shifted to H.
The power will be turned on automatically, and then the unit will start operations with the
Analog2-RCA source.
Confirm that the signal applied to the RCA input is put out from the RCA output. (The inter-
nal selector has been set to the RCA input.)
This mode can be operated even without the display unit.