![Pioneer AVR-W6100 UC Service Manual Download Page 56](http://html.mh-extra.com/html/pioneer/avr-w6100-uc/avr-w6100-uc_service-manual_326633056.webp)
AVR-W6100/UC
A
B
C
D
1
2
3
4
1
2
3
4
56
(3) Line adjustment 2 mode
(4) Dimmer parameter setting mode
[0 - 63]
[0 - 127]
[0 - 127]
[0 - 127]
[0 - 15]
[0 - 15]
[0 - 3]
63
127
127
127
15
15
3
BRIGHT
CONTRAST
SUB CON R
SUB CON B
SUB BRI R
SUB BRI B
SHARPNESS
Adjustment item
Bright (SA22: B7-2)
Contrast (SA25: B7-1)
Output sub contrast R
Output sub contrast B
Sub brightness R after
γ
circuit
Sub brightness B after
γ
circuit
Sharpness
Adjustable name
Adjustment
range
Settings or
written data
(DEC)
Adjustment item
Backlight output (MAX)
Backlight output(MIN)
Dimmer threshold (high)
Dimmer threshold (low)
External light point (high)
External light point (middle)
External light point (low)
Backlight point (high)
Backlight point (middle)
Backlight point (low)
Adjustable range
Adjustment
item
Settings or
written data
(DEC)
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
[0 - 255]
FF
FF
FF
FF
FF
FF
FF
FF
FF
FF
BL MAX
BL MIN
REF H
REF L
LUM H
LUM M
LUM L
BL H
BL M
BL L
DIMMER
LINE2
FF
CS
FF
CS
Notes:
1) CONTRAST data
The CONTRAST data is adjustable, and used as reference data for other adjustment items,
which is not memorized in the EEPROM.
2) SUB BRI R and SUB BRI B data
The displayed value or EEPROM written data is different from the setting value for the 2-screen
IC register (TC90A64F: IC1). (Before displayed on the screen, the setting value is converted via some software.)
Note: The dimmer point data is memorized in the EEPROM, but not treated as a CS item.
It's because the settings are adjustable by the user.
(MAX)
(TIP)
(MIN)
Displayed value
(adjusting value) (DEC)
15
14
9
8
7
1
0
15
14
9
8
7
1
0
0111
0110
0001
0000
1111
1001
1000
EEPROM written value.
(DEC)
2-screen IC register
setting (BIN)