AVIC-X940BT/XNUC
112
1
2
3
4
1
2
3
4
C
D
F
A
B
E
22. EXT CONNECTION TEST
Display information regarding externally exposed terminals or sensors such as illumination terminals,
vehicle speed pulse terminals, etc. Corresponding terminals are different depending on destination.
The status of item shown on the following figure is updated for every 0.5 second.
OK/NG Determination Condition
GYRO Test
OK/NG Determination of GYRO VOLTAGE
(Obtain the difference of gyro output value and offset standard value and perform OK/NG determination.)
Offset Standard Value : 1.35 [V]
Within 0.025 [V]
: Output Voltage OK (OK is displayed)
Within 0.025 ~ 0.05 [V] : Within the allowable aging tolerance (USABLE is displayed)
More than + 0.05 [V]
: Output Voltage NG (NG is displayed)
OK/NG Determination of DELTA SIGMA Value
(Perform variation determination from Gyro variance value)
Less than 30.0 : Variation OK (OK is displayed)
More than 30.0 : Variation NG (NG is displayed)
G SENSOR Test
OK/NG determination of G SENSOR VOLTAGE * Planned change of determination value.
(Obtain the difference of G Sensor output value and offset standard value and perform OK/NG determination.)
Offset Standard Value : 1.5 [V]
Within 0.2 [V]
: Output Voltage OK (OK is displayed)
Within 0.2 ~ 0.26 [V] : Within the allowable aging tolerance (USABLE is displayed)
More than 0.26 [V]
: Output Voltage NG (NG is displayed)
OK/NG Determination of DELTA SIGMA Value
(Perform variation determination from G Sensor variance value)
Less than 80.0 : Variation OK (OK is displayed)
More than 80.0 : Variation NG (NG is displayed)
* USABLE Range is the OK range of parts in which aging change is taken into consideration.
(USABLE is displayed on the screen)
* OK Range is the value determined when shipping test.
* At the Service Quarter, please determine OK products as parts if it is in the range of USABLE.
Temperature Sensor Output Value
(Display temperature AD value of temperature sensor in hexadecimal expression)
CC Part Temperature Sensor
2AB [- 30°C] ~ 10A [85°C]
: Normal Operation Range (determination is not displayed)
Other than above: NG
LCD Temperature Sensor
3F6 [- 25°C] ~ 015B [85°C] : Normal Operation Range (determination is not displayed)
Other than above: NG
NAVI Temperature Sensor
6 ~ 61 [°C]
: Normal Operation Range (determination is not displayed)
Other than above: NG
Summary of Contents for AVIC-X940BT
Page 21: ...AVIC X940BT XNUC 21 5 6 7 8 5 6 7 8 C D F A B E ...
Page 147: ...AVIC X940BT XNUC 147 5 6 7 8 5 6 7 8 C D F A B E ...
Page 161: ...AVIC X940BT XNUC 161 5 6 7 8 5 6 7 8 C D F A B E ...
Page 207: ...AVIC X940BT XNUC 207 5 6 7 8 5 6 7 8 C D F A B E ...
Page 255: ...AVIC X940BT XNUC 255 5 6 7 8 5 6 7 8 C D F A B E ...
Page 263: ...AVIC X940BT XNUC 263 5 6 7 8 5 6 7 8 C D F A B E ...