5.2 ERROR CODE LIST
-
Error Messages
If a CD is not operative or stopped during operation due to an error, the error mode is turned on and cause(s) of
the error is indicated with a corresponding number. This arrangement is intended at reducing nonsense calls from
the users and also for facilitating trouble analysis and repair work in servicing.
(1) Basic Indication Method
1) When SERRORM is selected for the CSMOD (CD mode area for the system), error codes are written to DMIN
(minutes display area) and DSEC (seconds display area). The same data is written to DMIN and DSEC. DTNO
remains in blank as before.
2) Head unit display examples
Depending on display capability of LCD used, display will vary as shown below. xx contains the error number.
8-digit display
6-digit display
4-digit display
ERROR-xx
ERR-xx
E-xx
(2) Error Code List
Code
Class
Displayed error code
Description of the code and potential cause(s)
10
Electricity
Carriage Home NG
CRG can't be moved to inner diameter.
SERVO LSI Com-
CRG can't be moved from inner diameter.
munication Error
-> Failure on home switch or CRG move mechanism.
Communication error between microcomputer and SERVO LSI.
11
Electricity
Focus Servo NG
Focusing not available.
-> Stains on rear side of disc or excessive vibrations on REWRITABLE.
12
Electricity
Spindle Lock NG
Spindle not locked. Sub-code is strange (not readable).
Subcode NG
-> Failure on spindle, stains or damages on disc, or excessive vibrations.
A disc not containing CD-R data is found.
Turned over disc are found, though rarely.
CD signal error.
17
Electricity
Setup NG
AGC protection doesn't work. Focus can be easily lost.
-> Damages or stains on disc, or excessive vibrations on REWRITABLE.
30
Electricity
Search Time Out
Failed to reach target address.
-> CRG tracking error or damages on disc.
44
Electricity
ALL Skip
Skip setting for all track.
(CD-R/RW)
50
Mechanism
CD On Mech Error
Mechanical error during CD ON.
-> Defective loading motor, mechanical lock and mechanical sensor.
A0
System
Power Supply NG
Power (VD) is ground faulted.
-> Failure on SW transistor or power supply (failure on connector).
Remarks: Mechanical errors are not displayed (because a CD is turned off in these errors).
Unreadable TOC does not constitute an error. An intended operation continues in this case.
Upper digits of an error code are subdivided as shown below:
1x: Setup relevant errors, 3x: Search relevant errors, Ax: Other errors.
Summary of Contents for AVIC-F700BT/XS/EW5
Page 8: ...AVIC F700BT XS UC 8 1 2 3 4 1 2 3 4 C D F A B E 2 SPECIFICATIONS 2 1 SPECIFICATIONS ...
Page 9: ...AVIC F700BT XS UC 9 5 6 7 8 5 6 7 8 C D F A B E ...
Page 10: ...AVIC F700BT XS UC 10 1 2 3 4 1 2 3 4 C D F A B E ...
Page 11: ...AVIC F700BT XS UC 11 5 6 7 8 5 6 7 8 C D F A B E 2 2 DISC CONTENT FORMAT ...
Page 12: ...AVIC F700BT XS UC 12 1 2 3 4 1 2 3 4 C D F A B E 2 3 PANEL FACILITIES ...
Page 13: ...AVIC F700BT XS UC 13 5 6 7 8 5 6 7 8 C D F A B E ...
Page 14: ...AVIC F700BT XS UC 14 1 2 3 4 1 2 3 4 C D F A B E ...
Page 15: ...AVIC F700BT XS UC 15 5 6 7 8 5 6 7 8 C D F A B E 2 4 CONNECTION DIAGRAM ...
Page 16: ...AVIC F700BT XS UC 16 1 2 3 4 1 2 3 4 C D F A B E ...
Page 21: ...AVIC F700BT XS UC 21 5 6 7 8 5 6 7 8 C D F A B E ...
Page 83: ...AVIC F700BT XS UC 83 5 6 7 8 5 6 7 8 C D F A B E ...
Page 84: ...AVIC F700BT XS UC 84 1 2 3 4 1 2 3 4 C D F A B E 9 2 EXTERIOR 1 C A B B C D D E E A ...
Page 90: ...AVIC F700BT XS UC 90 1 2 3 4 1 2 3 4 C D F A B E 9 5 CD MECHANISM MODULE ...
Page 125: ...AVIC F700BT XS UC 125 5 6 7 8 5 6 7 8 C D F A B E C a C b C b 2 3 CN701 4 6 A 6 ...
Page 137: ...AVIC F700BT XS UC 137 5 6 7 8 5 6 7 8 C D F A B E C SIDE B C CD CORE UNIT S10 5COMP2 ...