CD Section Test Mode (Aging Operation and Setup Analysis)
Play is performed in the CD normal mode. However, after setup, in the protection operation, such as FOK (focus),
LOCK (spindle), subcodes. sound skip and mechanical-unit errors, the error occurrence and a timeout, the occur-
rence cause and occurrence time are displayed. During setup, the operation status (internal RAM; CPOINT) of the
CD software is displayed.
(1) Entering the new test mode
See the test mode flowchart on Page 91.
(2) Correspondence of keys between the test mode and new test mode
Key
Test mode
New test mode
Regulator OFF
Regulator ON
In-play
Error or protection occurrence
BAND
Regulator ON
Regulator OFF
Error occurrence time or error cause switching
]
FWD-KICK
TRACK >
[
REV-KICK
< TRACK
NAVI/AV
TRACKING CLOSE
SCAN
DISP
TRACKING OPEN
MODE
EQ
FOCUS CLOSE
(ITP)
PAUSE
To new test mode
FOCUS MODE SWITCHING
AUTO/MANUAL
The conventional operation is performed for EJECT or CD ON/OFF.
(3) Error cause (error No.) codes
Error code
Type
Mode
Description
Details and cause
40
Electricity
PLAY
FOK=L
Focus slips off.
100mS
→
Damage, dirt, vibration and faulty
servomechanism.
41
Electricity
PLAY
LOCK=L
Spindle Lock slips off.
100mS
→
Damage, dirt, vibration and faulty
servomechanism.
42
Electricity
PLAY
Subcode NG
No subcode can be read.
500mS
→
Damage, dirt, vibration and faulty
servomechanism.
43
Electricity
PLAY
Sound skip
Last address memory operation.
occurrence
→
Damage, dirt, vibration and faulty
servomechanism.