[Data initialization]
[Outline]
Result of outermost circumference inspection and of calibration inspection (corrected value) are returned to their initial values.
As for the initialized items, the initial values are written into the EEPROM and the adjustment information is cleared.
[Display specifications]
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1
< T P d a t a i n t i a l i z e >
2
3
4
5
*
F a c t o r y
R a n g e
i n i t
6
*
F a c t o r y
C a l i b r a t i o n
i n i t
7
*
U s e r
R a n g e
i n i t
8
*
U s e r
C a l i b r a t i o n
i n i t
9
10
11
[
B A C K ]
:
D a t a
i n i t i a l i z e
12
[ A . M E N U ]
:
13
Conditions for the adjustment completion mark (*) to be lighted up.
(The mark will be lighted up if one of the multiple conditions is met.)
Outermost circumference inspection
When the outermost circumference inspection of the calibration for line has been completed normally.
16 point adjustment
When the 16 point adjustment of the calibration for line has been completed normally.
User outermost circumference inspection
When the user outermost circumference inspection of the calibration for line has been completed normally.
User 16 point adjustment
When the user 16 point adjustment of the calibration for line has been completed normally.
Conditions for the adjustment completion mark (*) to go out.
Outermost circumference inspection
When the above mentioned lighting conditions are not applicable.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
16 point adjustment
When the above mentioned lighting conditions are not applicable.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
User outermost circumference inspection
When the above mentioned lighting conditions are not applicable.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
When the above mentioned lighting conditions are not applicable.
When the adjusted value has been initialized (Data initialize).
When the EEPROM has been initialized.
[key operation spesifications]
MENU_ENTER
BACK
Determination of initializing item
Selected cursor down movement
To top menu
Operational
description
Remote
controller
key
Selected cursor up movement
R e t u r n t o m e n u