    PIMA Electronic Systems 

 

 

                 19 

control panel will first try to notify the contact through the main path, and will use the backup 
path if it fails. 

8.1.2

 

Communication Test 

 Path: select a contact’s path to be tested. 

  Press to Start: press and check that a notification is received by the contact. 

8.2

 

PIMA Cloud 

User Menu 

 Communication 

 PIMA Cloud 

To use the PIMAlink app to control the alarm system remotely, you will need to pair it with the 
cloud, receive a pairing code and use it for pairing the mobile phones of whoever will use the 

application. The pairing process is short. Before you pair the alarm system, make sure all the 
app users download and install it on their phones. 
The pairing code must be used within 10 minutes, or you will have to repeat the process and 
receive a new code (only for phones that have not been registered). 
1)

 

  Pair to PIMAlink: press and wait (shortly) for the code to appear on the screen. 

Immediately enter the code in the pairing screen of the PIMAlink app, in every phone. 

2)

 

  Unpair: press and disconnect 

FORCE

 and all your mobile phones from the cloud. 

8.3

 

Phone Notifications 

User Menu 

 Communication 

 Phone Notifications 

When the alarm is set off, 

FORCE

 calls the contact that is set to receive notifications, and sounds 

an alarm sound over the phone. 

Parameter 

Description 

Default  Range (sec) 

Alarm Sound 

The length of the alarm sound 

30 sec 

5-120 

Repeat Massage 

No. of times to redial and sound the notification 

1-8 

8.4

 

Remote Service 

User Menu 

 Communication 

 Remote Service 

Use the 

Remote Service menu when the service technician or CMS need to connect to the alarm 

system remotely. Go directly to this menu by pressing and holding key ‘6’ on the main menu

9

 

 

“Remote Service” and “CMS Registration” (next) allow connecting 

and controlling the alarm system. Only allow authorized technician 
to use these options! 

 

The CMS/Technician can connect to the system remotely only using 
a remote connection code.  

 

Parameter 

Description 

  Allow Access 

Now 

When you press this menu you allow a (authorized) technician to connect to 

the alarm system and control it remotely. 

  Over Network 

  Over Cellular 

1)

 

IP/URL: enter the data in the form of IP:Port (no space) when asked by 

a (authorized) technician. 

 

9

 System version 1.2 and higher 

Summary of Contents for CLW532

Page 1: ...FORCE Advanced Intruder Alarm System User Guide Including the Lite version Version 1 2 X...

Page 2: ...How to enter the menu and change the default codes 10 3 2 The user menu 11 Chap 4 Arming and Disarming 12 4 1 Arm Away 12 4 2 Arm in Home 1 4 12 4 3 Disarming 13 4 3 1 Disarming partitions 13 Chap 5...

Page 3: ...ngerous high voltages are present inside the control panel s enclosure Refer servicing to qualified personnel only This alarm system should be used with 230VAC 110VAC 50 60Hz protected by anti electri...

Page 4: ...s guide The Installation guide that includes the system and accessories installation and wiring instructions as well as the technician programming guide 1 1 Main features FORCE 8 onboard zones expanda...

Page 5: ...tems 5 1 2 Technical specifications AC power input 11 18V Backup battery DC input 13 8V Maximum output current 13 8VDC 1 1A FORCE Lite 0 9A Maximum idle output current 50mA EOL resistors programmable...

Page 6: ...age levels 0 12V Operating Voltage Range 9 14 VDC Current Consumption 50mA idle 90mA max Sizes 15 x 12 x 2cm Weight 235gr CE compliance Operating Temperature 10 to 55 C 2 1 3 Quick guide Figure 1 KLR...

Page 7: ...sirens and reporting the CMS where relevant and the contacts Alarm Press hold Medical 4 6 Fire 7 9 Panic 2 1 5 Keypad settings To view the Keypad Settings screen press and hold the menu key In this sc...

Page 8: ...keystroke presents a different character For example press 8 twice to enter the letter U The keystrokes and character table are described in the table and image below Key Characters 1 ABC2 abc2 2 DEF3...

Page 9: ...status LEDs refer to page 6 For Keypad alarms see section 2 1 5 above Silencing the keypad To silence the keypad s buzzer including the chime and keys completely press together the and keys Press aga...

Page 10: ...igit user code Every code is unique Do not use easy to guess codes like 3333 After saving a code it can not be revealed or restored in any way The codes 1234 and 5555 are reserved 3 1 2 How to enter t...

Page 11: ...ollows 1 Enter the Master code or 2 Press the menu key on a keypad and enter a user code in the code screen the user must have a permission to enter the menu see section 7 1 1 on page 16 Navigate in t...

Page 12: ...es without setting off the alarm Entering an instant zone will set off the alarm The technician can set the siren to beep to indicate on arming and disarming 4 2 Arm in Home 1 4 User Menu Arming Disar...

Page 13: ...en partitions are in use see Partitioning on page 25 a user can only disarm the partitions it is allocated to When disarming from a keypad the user partitions will be disarmed only when the keypad is...

Page 14: ...persists consult a technician 5 1 How to bypass on the fly User Menu Arming Disarming Arm Away Home To bypass a zone while arming the alarm system do the following 1 Enter Master or user code 2 The Zo...

Page 15: ...24 events are saved chronologically You can scroll between the events by pressing the arrow keys and see the details that follows Figure 2 The event memory screen 246 15 Oct 01 53 Event Memory Burglar...

Page 16: ...wireless key fob or panic button one per user to the user The key fob is used for arming and disarming and activate devices A wireless module is required refer to the technician 1 Press or to select a...

Page 17: ...Access Denied Message The permissions are as follows Disarming Event Memory Communication Users and Codes Time and Date Bypass Zones Auto Arming Technician Permit Control Remotely Use All Keypads Par...

Page 18: ...ions are Alarm from Burglary Panic Fire Duress Medical and Tamper Anti Mask zones detectors Custom Zone 1 5 faults Invalid Code7 and Arming Disarming events The control panel notifies by sounding an a...

Page 19: ...press and disconnect FORCE and all your mobile phones from the cloud 8 3 Phone Notifications User Menu Communication Phone Notifications When the alarm is set off FORCE calls the contact that is set t...

Page 20: ...nician to connect remotely with a special software 8 5 CMS Registration Registering the alarm system by the CMS is meant to prevent criminals from transmitting false transmissions After the registrati...

Page 21: ...ity of your alarm system and may also indicate on burglary setup Use the fault overriding option only when there is no other option fix the fault immediately or call for service technician To override...

Page 22: ...d Partitions User Menu System Options Armed Partitions View the numbers and names of the partitions that are currently armed Only the keypad s allocated partitions are displayed 9 4 Time and Date User...

Page 23: ...If a user stops the auto arming process by entering a user code set an interval in hours and minutes for arming retries FORCE will try to re arm itself according to the interval and the retry period...

Page 24: ...to enter its menu 2 FORCE allows you to be serviced by several CMS s The settings of each CMS are set separately and are protected by a password Only the Master technician can enter the Technician men...

Page 25: ...to the two partitions and so are the users who can therefor arm and disarm the two floors partitions Figure 3 Partitions example A Example B A two floor house each floor is defined as a separate part...

Page 26: ...How to clean the LCD screen To keep your keypad screen clean and without scratches follow the next instructions When you clean your monitor do not press down on the screen Do not spray any kind of li...

Page 27: ...age or the battery is exhausted and needs to be replaced An exhausted battery will not backup your alarm system if AC power is lost Tamper 1 2 Expander Keypad tamper Tamper 1 the tamper switch of the...

Page 28: ...out for a period set by the technician Internal External Siren Fault or open tamper switch System Time Not Set Occurs after a prolonged power outage when the back battery is exhausted Installer detail...

Page 29: ...to four Home modes areas Backup battery The backup battery enables the alarm system to continually safeguard the premises for a limited time at AC power fault Cutting power cords is common among burg...

Page 30: ...covers a defined area in the premises The alarm system is made of zones each triggers the alarm when it detects a movement or other changes The same as detectors there are various zone types such as...

Page 31: ...39 40 41 42 43 44 45 46 47 48 Zone Name Location 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 Zone Na...

Page 32: ...Code Code User Enrolled Add Delete User Manual Enrollment Auto Enrollment User Serial No Enroll User Status Serial No Signal Enroll Alarm Sound Voice Message Repeat Message Communication Contacts Phon...

Page 33: ...Date Time Date Year Cloud Auto Update Day Chime Zones Chime Active Inact Set per Zone Active Inactive Zone Auto Arming Timed No Movement Timed All Part No Mov All Part Partition Daily Hour Retry Inter...

Page 34: ...roduct warranty Warning The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week For various reasons includi...

Page 35: ......

Page 36: ...P N 4410460 441 046 0 Revision XX en B Mar 2019...

Reviews: