PX 30 and PX 120 Operating Manual
3-25
Operating Mode
Data (n)
Contents
Binary-coded
Data (1)
60
H
variable call-up
Data (2)
ID-Byte:
binary 0(?)(_)x0nnn
(nnn ... variable number binary coded,
x ... Bit is insignificant)
Data (3)
8-bit-binary
value
Data (4)
Data (5)
Data (6)
Data (4) to Data (6) or
Data (5) and Data (6) may be omitted
BCD-coded
Data (1)
60
H
variable call-up
Data (2)
ID-Byte:
binary 0(?)(_)(N)1nnn
(nnn ... variable number binary coded)
Data (3)
BCD-value 10
1
, 10
0
Data (4)
BCD-value 10
3
, 10
2
Data (5)
BCD-value 10
5
, 10
4
Data (6)
BCD-value 10
7
, 10
6
Data (7)
BCD-value 10
9
, 10
8
Data (4) ... Data (7) may be omitted.
ASCII-coded
Data (1)
60
H
variable call-up
Data (2)
ID-Byte:
binary 1(?)(_)(N)xnnn
(nnn ... variable number binary coded;
x ... Bit is insignificant)
Data (3)
1st ASCII-character (furthest right)
•
•
•
•
•
•
Data (12)
10th ASCII-character (furthest left)
Data (4) ... Data (12) may be omitted.
Special
Data (1)
70
H
Mode
Data (2)
binary xxyyyyyy
yyyyyy
Special function code,
binary coded
000001
Segment test on
000010
Segment test off
000011
Output version number
000110
Clear display
(See Page 3-11), x ... Bit is insignificant.
Activating Monitor
Data (1)
90
H
Mode
16-bit binary
value
32-bit binary
value
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com