Optical data

630831

630832

Operating range

0,0 - 25,0 m

0,0 - 25,0 m

Used wavelength range

640 nm

640 nm

Semiconductor outputs

630831

630832

Switching current per output

100 mA

100 mA

Times

630831

630832

Response time t1

1,00 ms

1,00 ms

Environmental data

630831

630832

Ambient temperature

Temperature range

-10 - 55 °C

-10 - 55 °C

Storage temperature

Temperature range

-20 - 70 °C

-20 - 70 °C

Vibration

In accordance with the standard

EN 60068-2-6

EN 60068-2-6

Frequency

10,0 - 55,0 Hz

10,0 - 55,0 Hz

Amplitude

0,50 mm

0,50 mm

Shock stress

In accordance with the standard

EN 60068-2-27

EN 60068-2-27

Number of shocks

6

6

Acceleration

30g

30g

Duration

11 ms

11 ms

Protection type

Housing

IP67

IP67

Mechanical data

630831

630832

Material

Housing

ABS

ABS

Max. torque setting for fixing
screws

1,50 Nm

1,50 Nm

Dimensions

Height

50,0 mm

50,0 mm

Width

66,0 mm

66,0 mm

Depth

18,0 mm

18,0 mm

Weight

30 g

30 g

Order reference

Product type

Features

Order no.

PSEN op3.1 Receiver NO/NC
M12

Single-channel light beam device, receiver with NO/
NC outputs

630 831

PSEN op3.2 Emitter M12

Single-channel light beam device, transmitter

630 832

Summary of Contents for PSEN op3.1

Page 1: ...PSEN op3 1 3 2 Operating Manual 1003607 EN 02 PSEN sensor technology Accessories...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...ion has been made e g exchanging components on the PCB boards soldering work etc Using the documentation This document is intended for instruction Only install and commission the product if you have r...

Page 4: ...vides information on special fea tures Overview Intended use The PSEN op3 1 3 2 may only be used to implement the muting function on a safety light grid without muting sensors Use of the single channe...

Page 5: ...ough hole for attachment 7 Through hole for attachment 8 Rotatable connector plug block Wiring Information given in the Technical details 8 must be followed Use copper wiring with a temperature stabil...

Page 6: ...ck by 180 1 Setting INFORMATION The sensitivity controller can be rotated by a maximum of 240 If the trimmer is overwound the product will be destroyed Never rotate the trimmer beyond the maximum posi...

Page 7: ...using three screws M4 minimum length 25 mm Attach receiver 1 On the mounting surface drill three M4 holes in the required position for the receiver in accordance with the position of the through holes...

Page 8: ...f Light beam is not interrupted 3 Green LED Operating status and luminosity LED on Light beam is detected device is ready for operation LED off Light beam is not detected caused by con taminations for...

Page 9: ...60068 2 6 EN 60068 2 6 Frequency 10 0 55 0 Hz 10 0 55 0 Hz Amplitude 0 50 mm 0 50 mm Shock stress In accordance with the standard EN 60068 2 27 EN 60068 2 27 Number of shocks 6 6 Acceleration 30g 30g...

Page 10: ...p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...

Reviews: