middle of the first deviating mirror. The height of the laser pointer 

and the height where the pointer hits have to be identical. 

 

Repeat the procedure and align the laser pointer at the bottom 

part of the unit. Repeat these steps several times, if necessary.  

 

Align the first deviation mirror so that the laser beam hits the 

second deviating mirror in the position described before. 

 

Turn the mounting brackets to set the angle, an when the 

required position is reached, tighten the screws. Use the slot 

holes at the deviating mirror and/or adapt the inclination of the 

floor bracket by adding adjusting washers. 

 

Align the second deviating mirror in the same way and make sure 

that the laser hits the receiver unit. 

 

Insert the laser pointer in the upper part of the receiver unit and 

align it so that the laser beam reflected by the deviating mirrors 

hits the transmitter unit. 

 

Repeat the same process with the laser pointer in the lower part 

of the receiver unit. 
 

 

 

Fig. 2 

 

 

 

 

PSEN op Mirror Bracket Kit/1 

Screw M6x50 

Summary of Contents for PSEN op Mirror/1

Page 1: ...isplaced accidentally or by strong vibrations We recommend that you use the PSEN op Protective Column 1 accessories where the deviating mirror can be fixed with the corresponding assembly kits In an e...

Page 2: ...ct positions where the deviating mirrors and the transmitter and receiver units of the light curtain are to be installed Fix the floor bracket to the defined point on the floor and note that their axe...

Page 3: ...he laser beam hits the second deviating mirror in the position described before Turn the mounting brackets to set the angle an when the required position is reached tighten the screws Use the slot hol...

Page 4: ...installed on the PSEN op Protective Column 1 PSEN op Protective Column 1 is a column made of aluminium and a base plate made of steel The base plate consists of 2 plates that can be adapted to the gr...

Page 5: ...PSEN op2B 4 090 PSEN op4B 4 090 PSEN opSB 4B 4 090 PSEN op2B 4 120 PSEN op4B 4 120 PSEN opSB 4B 4 120 PSEN op Mirror 060 1 PSEN op xx s xx 015 1 PSEN op xx s xx 030 1 PSEN op xx s xx 045 1 PSEN op Mi...

Page 6: ...Co KG Felix Wankel Stra e 2 73760 Ostfildern Germany Telephone 49 711 3409 0 Telefax 49 711 3409 133 E Mail pilz gmbh pilz de Original document Dimensions PSEN op Mirror 015 1 Fig 3 shows PSEN op Mir...

Page 7: ...op Mirror 1 in the length 60 190 cm with installed PSEN op Mirror Bracket Kit 1 Product type L1 mm L2 mm L3 mm PSEN op Mirror 060 1 545 376 580 PSEN op Mirror 090 1 845 676 880 PSEN op Mirror 120 1 1...

Reviews: