PSEN ma1.4p-51
Operating Manual PSEN ma1.4p-51
22127-EN-05
19
Electrical data
506336
506338
Max. switching current, safety con-
tacts
0,2 A
0,2 A
Max. breaking capacity, safety con-
tacts
5 W
5 W
Max. switching current, auxiliary
contacts
10 mA
10 mA
Times
506336
506338
Reaction time (actuator removed)
2 ms
2 ms
Environmental data
506336
506338
Ambient temperature
Temperature range
-10 - 55 °C
-10 - 55 °C
Climatic suitability
In accordance with the standard
IEC 60068-2-30
IEC 60068-2-30
Humidity
93 % r. h. at 40 °C
93 % r. h. at 40 °C
Max. operating height above sea
level
2000 m
2000 m
EMC
EN 60947-5-3
EN 60947-5-3
Vibration
In accordance with the standard
EN 60947-5-2
EN 60947-5-2
Frequency
10 - 55 Hz
10 - 55 Hz
Amplitude
1 mm
1 mm
Shock stress
Acceleration
30g
30g
Duration
11 ms
11 ms
Airgap creepage
Pollution degree
3
3
Rated insulation voltage
25 V
25 V
Rated impulse withstand voltage
0,33 kV
0,33 kV
Protection type
Housing
IP6K9K
IP6K9K
Connector
IP67
IP67
Mechanical data
506336
506338
Actuator 1
PSEN ma1.4-03mm
PSEN ma1.4-10mm
Typ. Hysteresis
2,5 mm
3,5 mm
Operating distances
Assured operating distance Sao
3 mm
10 mm
Min. operating distance Somin
0,0 mm
0,0 mm
Typical operating distance So
3,5 mm
12,5 mm
Assured release distance Sar
12 mm
22 mm
Typical release distance Sr
6 mm
16 mm
Repetition accuracy switching
distances
6 %
6 %
Min. distance between safety
switches
50 mm
50 mm
Sensor flush installation in accord-
ance with EN 60947-5-2
Yes, follow installation
guidelines
Yes, follow installation
guidelines