PSEN cs5.13 M12/8 EX
Operating Manual PSEN cs5.13 M12/8 EX
22218-EN-04
| 20
CAUTION!
Extension of delay-on de-energisation
When several (n) devices are connected in series, the delay-on de-ener-
gisation time adds with the number of interconnected safety switches.
The max. delay-on de-energisation is made up of the
risk time (see
+ (n-1) x max. delay-on de-energisation of the inputs
+ max. delay-on de-energisation of the evaluation device
}
When making series connections using SDD, only use the following passive junctions.
– PSEN ix2 F4 code
– PSEN ix2 F8 code
– PSEN Y junction M8-M12/M12 PIGTAIL
– PSEN Y junction M12-M12/M12 PIGTAIL
– PSEN Y junction M12 SENSOR
– PSEN Y junction M12 cable channel