PSEN cs4.1n
Operating Manual PSEN cs4.1n
22180-EN-05
11
Wiring
Please note:
}
Information given in the "Technical details" must be followed.
}
The power supply must meet the regulations for extra low voltages with protective sep-
aration (SELV, PELV).
}
The inputs and outputs of the safety switch must have a protective separation to
voltages over 60 VDC.
INFORMATION
Only use safety relays with a 24 VDC supply voltage. Safety relays with a
wide-range power supply or in AC device versions have internal potential
isolation and are not suitable as evaluation devices.
}
The supply voltage to the safety switch must be protected with a 2 A to 4 A quick-acting
fuse.
}
Ensure the wiring and EMC requirements of EN 60204-1 are met.
Pin assignment, connector and cable
1
2
3
5
4
5-pin M12 male connector
PIN
Pin
designation
Function
Wire colour
1
A1
+24 UB
Brown
2
12
Output, channel1
White
3
A2
0 V UB
Blue
4
22
Output, channel2
Black
5
-
Do not connect
Grey
The wire colour also applies for the cable available from Pilz as an accessory.