PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05
8
Unit features
}
Positive-guided relay outputs:
–
3 safety contacts (N/O), instantaneous
–
2 safety contacts (N/O), delay-on de-energisation
}
Connection options for:
–
E-STOP pushbuttons
–
Safety gate limit switches
–
Start buttons
–
Light grids and safety switches with detection of shorts across contacts
}
Delay time fixed or selectable
}
Possible to cancel delay time
}
LED display for:
–
Supply voltage
–
Switch state of the safety contacts
–
Start circuit
}
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
}
See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
}
The circuit is redundant with built-in self-monitoring.
}
The safety function remains effective in the case of a component failure.
}
The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.