Overview
Operating Manual PNOZ ms2p TTL
1001722-EN-03
7
2
Overview
2.1
Scope
}
Expansion module PNOZ ms2p TTL (Coated Version)
}
Jumper
2.2
Unit features
Using the product PNOZ ms2p TTL (Coated Version):
Speed monitor for connection to a base unit from the configurable control system
PNOZmulti
The product has the following features:
}
Monitoring of 2 independent axes
}
Connection per axis
– 1 incremental encoder
or
– 2 proximity switches
or
– 1 incremental encoder and 1 proximity switch
}
Measured variables:
– Standstill
– Speed (8 values can be set)
– Direction of rotation
}
Axis types, input device types and start mode can be selected in the PNOZmulti Config-
urator
}
Status indicators for
– Supply voltage
– Incremental encoder
– Proximity switch
– Axis status, standstill and excess speed
– Faults on the system
}
Proximity switch connection technology: Plug-in connection terminals (either cage
clamp terminal or screw terminal)
}
Incremental encoder connection technology:
RJ45 female connector
}
Galvanic isolation between the connections X1, X12 and X22
}
Max. 4 speed monitors can be connected to the base unit
}
Coated version:
Increased environmental requirements (see
Technical details [
29]
)