Operation
Operating Manual PNOZ m EF 2MM
1003107-EN-10
42
7
Operation
The PNOZmulti system is ready for operation when the "POWER" and "RUN" LEDs on the
base unit are lit continuously.
7.1
LED indicators
Legend
LED on
LED flashes
Please note that these displays may also appear in combination.
LED
Fault
Power
Run
Diag
Fault
Axis 1
Axis 2
No supply voltage
Expansion module PNOZ m EF 2MM is in a
STOP condition.
Expansion module PNOZ m EF 2MM is run-
ning without error, no axis is active.
Axis 1 is not yet ready.
Axis 2 is not yet ready.
Axis 1 is configured and is running.
Axis 2 is configured and is running.
Internal error on the expansion module PNOZ
m EF 2MM or on the overall system. Expan-
sion module is in a safe condition.
External error on the expansion module
PNOZ m EF 2MM or on the overall system.
Expansion module is in a safe condition.
Implausible sensor signal at axis 1.
Implausible sensor signal at axis 2.
Implausible sensor signal at axis 1
or
Internal error.
Implausible sensor signal at axis 2
or
Internal error.
7.2
Behaviour with implausible sensor signals
Implausible sensor signals (e.g. frequency difference between Track A and B or the ratio of
AB to Z is not correct) do not lead to an FS stop of the PNOZmulti system.
However, the error is displayed through the LEDs at the device and through an error stack
entry. All the safety functions that refer to the Motion Monitoring area will be deactivated.