Function description
Operating Manual PIT m4SEU
1004648-EN-02
| 20
DIP switch setting
Switching behaviour
of operating mode
(OM)
Communication
modes
Operating
mode lock
and operat-
ing mode
preselec-
tion
[D1]: Default setting
4 3 2 1
Off
On
OM1-OM4:
OM retention
Transmitter or hand-
shake-controlled com-
munication mode
OM5:
Service fallback
[D2]
4 3 2 1
Off
On
OM retention
Transmitter or hand-
shake-controlled com-
munication mode
[D3]
4 3 2 1
Off
On
OM fallback
Transmitter or hand-
shake-controlled com-
munication mode
[D4]
4 3 2 1
Off
On
OM storage
Transmitter or hand-
shake-controlled com-
munication mode
[D5]
4 3 2 1
Off
On
OM1-OM4:
OM retention
Advanced communica-
tion mode
x
OM5:
Service fallback
[D6]
4 3 2 1
Off
On
OM retention
Advanced communica-
tion mode
x
[D7]
4 3 2 1
Off
On
OM fallback
Advanced communica-
tion mode
x
[D8]
4 3 2 1
Off
On
OM storage
Advanced communica-
tion mode
x
DIP configuration
NOTICE
It is
essential
to note that only the DIP switch settings described above will
be assessed as valid. With all other DIP switch settings, the device switches
to a "Device error" fault condition.