Inputs

774595

Number

2

Relay outputs

774595

Max. short circuit current IK

1 kA

Utilisation category

In accordance with the standard

EN 60947­4­1

Safety contacts, AC1 at

240 V

Max. current

8,0 A

Min. current

0,01 A

Max. power

2000 VA

Safety contacts, DC 1 at

24 V

Max. current

8,0 A

Min. current

0,01 A

Max. power

200 W

Utilisation category

In accordance with the standard

EN 60947­5­1

Safety contacts, AC15 at

230 V

Max. current

5,0 A

Safety contacts DC13 (6 cycles/min) at

24 V

Max. current

7,0 A

Utilisation category in accordance with UL

Voltage

240 V AC G. P.

With current

8,0 A

Voltage

24 V DC G. P. Resistive

With current

5,0 A

Pilot Duty

B300, C600, R300

Contact fuse protection external, safety contacts

In accordance with the standard

EN 60947­5­1

Max. melting integral

240 A²s

Blow­out fuse, quick

10 A

Blow­out fuse, slow

6,00 A

Blow­out fuse, gG

10 A

Circuit breaker, 24V AC/DC, characteristic B/C

6 A

Contact material

 0,2 µm Au

Conventional thermal current while loading sev­
eral contacts

774595

Ith per contact at UB DC

Conv. therm. current with 1 contact

8,00 A

Conv. therm. current with 2 contacts

8,00 A

Conv. therm. current with 3 contacts

6,50 A

Conv. therm. current with 4 contacts

5,60 A

Conv. therm. current with 5 contacts

5,00 A

Summary of Contents for 774595

Page 1: ...PZE X5 Operating Manual 1003301 EN 05 Safety relays...

Page 2: ...KG Copies may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET...

Page 3: ...fety 5 Unit features 5 Safety features 5 Block diagram terminal configuration 6 Function description 6 Installation 7 Wiring 7 Preparing for operation 8 Operation 8 Status indicators 8 Faults Interfer...

Page 4: ...This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING This warning must b...

Page 5: ...regulations are met especially those relating to safety Any guarantee is rendered invalid if the housing is opened or unauthorised modifica tions are carried out Note for overvoltage category III If v...

Page 6: ...ice without delay on de energisation and it is used to expand a safety circuit The contact expansion module is driven by a base unit e g emergency stop relay Functional procedure when the supply volta...

Page 7: ...cal details 9 must be followed The outputs 13 14 23 24 33 34 43 44 53 54 are safety contacts To prevent contact welding a fuse should be connected before the output contacts see Technical details Calc...

Page 8: ...ss contacts K1 K2 U Y4 Y3 PZE U Feedback loop Y1 and Y2 are feedback loop in puts on the base unit Operation Status indicators Power Supply voltage is present CH 1 Safety contacts of channel 1 are clo...

Page 9: ...95 Approvals CCC CE EAC Eurasian T V cULus Listed Electrical data 774595 Supply voltage Voltage 24 V Kind DC Voltage tolerance 15 10 Output of external power supply DC 3 5 W Residual ripple DC 20 Cont...

Page 10: ...lisation category in accordance with UL Voltage 240 V AC G P With current 8 0 A Voltage 24 V DC G P Resistive With current 5 0 A Pilot Duty B300 C600 R300 Contact fuse protection external safety conta...

Page 11: ...95 Climatic suitability EN 60068 2 78 Ambient temperature Temperature range 10 55 C Storage temperature Temperature range 40 85 C Condensation during operation Not permitted EMC EN 60947 5 1 EN 61000...

Page 12: ...D EN ISO 13849 1 2008 TM year PL e Cat 4 SIL CL 3 2 31E 09 SIL 3 2 03E 06 20 All the units used within a safety function must be considered when calculating the safety characteristic data INFORMATION...

Page 13: ...ategory AC15 Contact service life 4 000 000 cycles Provided the application requires fewer than 4 000 000 cycles the PFH value see tech nical details can be used in the calculation To increase the ser...

Page 14: ...et the requirements of the directive 2006 42 EC for ma chinery of the European Parliament and of the Council The complete EC Declaration of Conformity is available on the Internet at www pilz com supp...

Page 15: ...mo PMCprotego PMCtendo PMD PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would poi...