background image

PDP67 F 8DI ION HP

Operating Manual 1002225-EN-05

}

Decentralised periphery

Summary of Contents for 773601

Page 1: ...PDP67 F 8DI ION HP Operating Manual 1002225 EN 05 Decentralised periphery...

Page 2: ...t is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be...

Page 3: ...Introduction Operating Manual PDP67 F 8DI ION HP 1002225 EN 05 3 INFORMATION This gives advice on applications and provides information on special fea tures...

Page 4: ...dustrial environment up to protection type IP67 The product has the following features Protection type IP67 8 inputs for connecting 8 single channel or 4 dual channel sensors 8 outputs which can be c...

Page 5: ...4 Inputs X5 Interface to the control system or to X6 on the upstream module X6 Interface to X5 on the downstream module X7 Interface to the 24 V supply or to X8 on the upstream module X8 Interface to...

Page 6: ...Overview Operating Manual PDP67 F 8DI ION HP 1002225 EN 05 6 IO0 IO7 2 3 Scope of supply Decentralised input module PDP67 F 8DI ION HP PDP67 F 8DI ION HP VA 4 blind plugs...

Page 7: ...ith regard to in terference 3 2 Safety regulations 3 2 1 Use of qualified personnel The products may only be assembled installed programmed commissioned operated maintained and decommissioned by compe...

Page 8: ...sposal In safety related applications please comply with the mission time TM in the safety re lated characteristic data When decommissioning please comply with local regulations regarding the disposal...

Page 9: ...n be used as standard outputs as test pulse outputs or as 24 VDC outputs The test pulse outputs are suitable for testing the sensor wiring All safety related inputs must operate in accordance with the...

Page 10: ...mounting distances will depend on which plug in connectors are used and on the bending radius of the cables Unused connectors should be sealed using blind plugs To install the system proceed as follo...

Page 11: ...t monitor must be in accordance with the relevant national regulations e g EN 60204 1 NFPA 79 17 7 NEC Article 250 INFORMATION The module s output circuits have been designed to guarantee maximum safe...

Page 12: ...capacity of the M12 plug in connector is 4 A per connector You must ensure that this value is not exceeded Exceeding the permitted current load capacity can damage the plug in connector Please note th...

Page 13: ...ly Voltage Operating Manual PDP67 F 8DI ION HP 1002225 EN 05 13 2 3 4 1 5 X7 male connector X8 female connector 4 1 2 3 5 Fig Pin assignment for the supply voltage Key 1 24 VDC 2 24 VDC 3 0 V 4 0 V 5...

Page 14: ...embled cable can be used to connect the inputs and outputs see order ref erence We recommend you use pre assembled Pilz connectors to connect the inputs and test pulse outputs see order reference CAUT...

Page 15: ...ST output 2 3 4 1 5 Interface to the link module X5 Assignment 5 pin M12 male connector A coded 1 VCC 2 CAN 3 GND 4 CAN 5 Shield 2 3 4 1 5 Interface to the next decent ralised module X6 Assignment 5...

Page 16: ...suitable for input devices with frequent and infrequent operation in accord ance with EN ISO 13849 1 up to PL d and EN IEC 62061 up to SIL CL 2 The input device must be approved for failsafe applicati...

Page 17: ...n area and its respective regulations this connection dia gram is suitable for input devices with frequent operation and diverse channels in accordance with EN ISO 13849 1 up to PL e and EN IEC 62061...

Page 18: ...les to both input devices will not be detected Depending on the application serious injury or death may result Avoid short circuits by Appropriate wiring Wiring in accordance with the requirements of...

Page 19: ...ts for short circuit to 24 V and correct func tionality Short circuits that short out the input device cable from the test pulse to the in put device and cable from the input device to the input will...

Page 20: ...Wiring Operating Manual PDP67 F 8DI ION HP 1002225 EN 05 20 24 V L L Test pulse T0 Single channel fail safe input device Please ensure safety regulations and EMC guidelines are met...

Page 21: ...tions This type of connection is mainly used for signal inputs with infrequent operation As the test pulses are permanently assigned to the inputs all short circuits will be de tected with the excepti...

Page 22: ...em established Yellow Error in the connection to the control system Flashing stops a max of 1 min after the fault has been rectified No connection to control system established Input LEDs Green 1 sign...

Page 23: ...L508 4 A 4 A Terminal voltage when switching off inductive loads 45 V 45 V Permitted loads inductive capacitive resistive inductive capacitive resistive Inputs 773601 773615 Number 8 8 Signal level at...

Page 24: ...ordance with the standard EN 60068 2 14 EN 60068 2 14 Temperature range 30 60 C 30 60 C Storage temperature In accordance with the standard EN 60068 2 1 2 EN 60068 2 1 2 Temperature range 40 70 C 40 7...

Page 25: ...voltage Type of potential isolation Basic insulation Basic insulation Rated surge voltage 500 V 500 V Potential isolation between SC output and int bus volt SC output and int bus volt Type of potentia...

Page 26: ...N ISO 13849 1 2015 TM year Input SC inputs 1 channel PL d Cat 2 SIL CL 2 9 06E 09 20 SC inputs 2 channel PL e Cat 4 SIL CL 3 1 24E 09 20 Bus interface Bus interface All PL e Cat 4 SIL CL 3 1 94E 09 20...

Page 27: ...S67 Cable M8sf M12sm Cable straight M12 connector straight M8 socket 4 pin 10 m 380 202 PSS67 Cable M8sf M12sm Cable straight M12 connector straight M8 socket 4 pin 30 m 380 203 PSS67 Cable M8sf M12sm...

Page 28: ...straight B coded 10 m 380 252 PSS67 Supply Cable IN af OUT am Cable IN socket angled OUT con nector angled B coded 3 m 380 253 PSS67 Supply Cable IN af OUT am Cable IN socket angled OUT con nector an...

Page 29: ...straight 5 pin A coded 380 309 PSS67 M12 connector Connector M12 angled 5 pin A coded 380 310 PSS67 M12 connector Socket M12 angled 5 pin A coded 380 311 PSS67 M12 connector Connector M12 straight 5...

Page 30: ...p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...

Reviews: