PNOZ s22
Operating Manual PNOZ s22
22170-EN-04
16
Where standards are undated, the 2017-01 latest editions shall apply.
The values for conventional thermal current stated in the technical details apply when the
contacts from Ext.1/O0
and
Ext.2/O1 are under load simultaneously.
Conventional thermal current when either the contacts from Ext.1/O0
or
the contacts from
Ext.2/O1 are under load:
Number of contacts
in total
I
th
[A] per contact
1
6 A
2
6 A
3
5 A
Safety characteristic data
Operating
Mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
Safety con-
tacts, in-
stantaneous
PL e
Cat. 4
SIL CL 3
2,31E-09
SIL 3
2,03E-06
20
NOTICE
The safety-related characteristic data applies per channel of the contact ex-
pansion block. The safety-related characteristic data of the base unit and all
other devices that are used must be taken into account when calculating the
safety function. We recommend that you use the PAScal software tool to
calculate the safety function's SIL/PL values.