PSEN opII3B Series
Operating Manual PSEN opII3B Series
1004845-EN-02
| 19
R
x2
Receiver from the second safety light curtain
[1] Minimum distance D
LV
between two safety light curtains that are aligned
}
Working distance A < 3 m: D
LV
= 2 x D = 0.262 m
}
Working distance A ≥ 3 m: D
LV
= 2 x A x tan 2.5°
[2] Working distance A
[3] Minimum distance D, dependent on the working distance
[4] Working distance (≤ 3 m) with constant minimum distance D = 0.262 m
With beam coding
[1]
[2]
[3]
T
xA
R
xA
T
xB
R
xB
Legend
T
xA
Transmitter from the first safety light curtain
R
xA
Receiver from the first safety light curtain
T
xB
Transmitter from the second safety light curtain
R
xB
Receiver from the second safety light curtain
[1]
Minimum distance between two aligned safety light curtains with beam coding
[2]
Distance between the transmitter of the first safety light curtain and the receiver of
the second safety light curtain
[3]
Distance between the transmitter of the second safety light curtain and the receiver
of the first safety light curtain
Minimum distance between two aligned safety light curtains with beam coding
Lower value of the distances
[2] and [3]
Minimum distance between safety light curtains
that are aligned in parallel
[1]
}
170 mm resolution
[2] < 2.5 m or [3] < 2.5 m
2 x D = 262 mm
[2] ≥ 2.5 m and [3] ≥ 2.5 m
-
}
300 mm resolution
[2] < 10 m or [3] < 10 m
2 x 10 m x tan α
[2] ≥ 10 m and [3] ≥ 10 m
-