PSEN opII3F Series
Operating Manual PSEN opII3F Series
1003504-EN-01
26
[1]
[1]
Mount the holder on the end cap on the wiring side
of the safety light grid
Ensure that the holder is flush with the end cap (see
diagram).
Attach the holder to the end cap with the tightening
screws included in delivery.
[1] Torque setting 0,7 Nm
[1]
[2]
Mount the flexible bracket (swivel mount) on the
holder on both the connection and wiring sides of
the safety light grid.
Push the flexible bracket over the holder. The flexible
bracket must lie flush with the holder.
Fix the flexible bracket in place with the clamping
screw [1] and the nut [2].
The screw connection is only tightened to the final
torque when the assembly is orientated.
[1]
[2]
[3]
[4]
a
Uneven installation surfaces can be compensated for
with the standard installation kit to a limited extent
only.
Please note the following when installing the
safety light grid [1]:
}
The angle [4] of the flexible bracket [3] on the
holder [2] may not be more than 2°.
}
The flexible bracket [3] must be seated on one side
of the holder [2].