Pilz 542 113 Operating Manual Download Page 27

PSEN cs6.11n

Operating Manual PSEN cs6.11n
1004127-EN-03

27

Accessories

Installation materials

Product type

Features

Order no.

PSEN bracket

Mounting bracket

532 110

PSEN mag/cs bracket
straight

Mounting aid

532 111

PSEN screw M4x20 10pcs

Safety screws made from stainless steel with one-way slot

540 313

PSEN screw M4x26 10pcs

Safety screws made from stainless steel with one-way slot

540 314

PSEN cs1/2 bracket cable
fix

Mechanical protection against defeat, protecting against unau-
thorised cable disconnection or damage for safety switches
PSENcode cs1/2, PSENcode cs5/6 M12, PSENslock

532 112

Cable

Product type

Connection 1

Connection 2

Length

Order No.

PSS67/PDP67 cable
M12-5sf

Straight, M12, 5-pin, socket Straight, M12, 5-pin,

connector

3 m

380 208

5 m

380 209

10 m

380 210

20 m

380 220

30 m

380 211

PSS67/PDP67 cable
M12-5af

Angled, M12, 5-pin, socket

Angled, M12, 5-pin,
connector

3 m

380 212

5 m

380 213

10 m

380 214

30 m

380 215

PSEN cable M12-5sf

Straight, M12, 5-pin, socket Open cable

3 m

630 310

5 m

630 311

10 m

630 312

20 m

630 298

30 m

630 297

PSEN cable M12-5af

Angled, M12, 5-pin, socket

Open cable

3 m

630 347

5 m

630 348

10 m

630 349

30 m

630 350

Summary of Contents for 542 113

Page 1: ...PSEN cs6 11n Operating Manual 1004127 EN 03 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...unction description 9 Block diagram 9 Operating distances 9 Lateral and vertical offset 11 Wiring 13 Pin assignment connector and cable 13 Connection to evaluation devices 14 Single connection 14 Conn...

Page 4: ...Contents Operating Manual PSEN cs6 11n 1004127 EN 03 4 Order reference 26 System 26 Accessories 27 EC declaration of conformity 28...

Page 5: ...rticularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive m...

Page 6: ...type 4 The safety switch may only be used with the corresponding actuator PSEN cs6 11 M12 The safety level PL e Cat 4 SIL CL 3 is only achieved if the safety outputs use 2 channel processing The foll...

Page 7: ...evices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibilit...

Page 8: ...tuators are used these must be installed as described in Installation 16 If the original actuators are replaced with substitute actuators the ori ginal actuators must be destroyed before disposal Do n...

Page 9: ...fety output 12 Safety output 22 Signal output Y32 Yes High High High No Low Low Low Block diagram A1 A2 Power Receiver Actuator 12 22 Y32 Operating distances Alignment of the actuator Operating distan...

Page 10: ...On Off Typical course of change in the holding force as the distance from the switch to the actuator increases with frontal approach 0 5 10 15 20 25 30 35 0 5 10 15 20 25 holding force N distance mm...

Page 11: ...when aligning to the triangle marking Actuator aligned to the square marking on the switch 1 2 3 4 4 5 6 4 0 14 12 8 4 0 12 8 4 8 4 0 12 14 7 4 14 Legend 1 Hysteresis 2 Typical operating distance SO 3...

Page 12: ...gle marking Actuator aligned to the square marking on the switch 4 5 7 8 1 3 2 8 4 0 12 8 4 0 12 8 4 12 16 8 4 0 12 16 16 16 6 Legend 1 Hysteresis 2 Typical operating distance SO 3 Typical release dis...

Page 13: ...Safety relays with a wide range power supply or in AC device versions have internal potential isolation and are not suitable as evaluation devices The supply voltage to the safety switch must be prot...

Page 14: ...0 V the safety switch may be dam aged as a result Connect the signal output Y32 to a consumer e g to the input on a control system or leave the signal output unconnected Also note the max current see...

Page 15: ...evaluation device is described in the operating manual for the evaluation device Make sure that the connection is made in accordance with the specifications in the operating manual for the selected e...

Page 16: ...permitted additional learning procedures is reduced by 1 NOTICE The actuator must not be removed during the learning procedure This actuator cannot be retaught on the same safety switch Installation...

Page 17: ...ot be used as an end stop For simpler installation the mounting brackets see Order reference for Accessories 27 can be used The actuator should be protected from unauthorised removal and from contamin...

Page 18: ...e the actuator and sensor see Dimensions in mm 21 2 Use a screw to fix the sensor to the mounting surface Make sure that the square marking on the sensor can be operated using the actuator from the ri...

Page 19: ...the safety switch and actuator are installed facing each other in parallel Operating dis tances may deviate if other arrangements are used Note the maximum permitted lateral and vertical offset see O...

Page 20: ...plete Switch voltage off and then on again Error display LED status Switch status Remedy measure Device Safety Gate Input red Off Off Internal error on switch Change the switch red yellow yellow Supp...

Page 21: ...1n 1004127 EN 03 21 LED status Switch status Remedy measure Device Safety Gate Input Off yellow yellow Switch doesn t start Change the switch Dimensions in mm Safety switch 1 2 90 26 4 7 5 22 7 4 11 6...

Page 22: ...PSEN cs6 11n Operating Manual PSEN cs6 11n 1004127 EN 03 22 Actuator 18 22 2 7 5 4 5 4 8 3 90 22 90 19 7 5 9 5 Legend 1 Square marking 2 Triangle marking 3 LEDs 4 Semicircle marking...

Page 23: ...W Max switching frequency 3 Hz Max cable capacitance at the safety outputs No load PNOZ with relay contacts 40 nF PNOZmulti PNOZelog PSS 40 nF Max inrush current impulse Current pulse A1 0 5 A No loa...

Page 24: ...ge 40 85 C Climatic suitability In accordance with the standard EN 60068 2 30 Humidity 93 r h at 40 C Max operating height above sea level 4000 m EMC EN 60947 5 3 Vibration In accordance with the stan...

Page 25: ...ing screws 1 Nm Dimensions Height 26 4 mm Width 101 6 mm Depth 19 mm Actuator dimensions Height 18 mm Width 90 mm Depth 19 mm Weight of safety switch 75 g Weight of actuator 60 g Weight 135 g Where st...

Page 26: ...ble protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 27: ...st unau thorised cable disconnection or damage for safety switches PSENcode cs1 2 PSENcode cs5 6 M12 PSENslock 532 112 Cable Product type Connection 1 Connection 2 Length Order No PSS67 PDP67 cable M1...

Page 28: ...M12 thread in stainless steel 773 614 PDP67 F 8DI ION HP VA Decentralised input module IP67 for PNOZmulti with M12 thread in stainless steel and additional supply voltage 773 615 EC declaration of co...

Page 29: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Reviews: