For your safety
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If spare actuators are used, these must be installed as described in
.
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
}
Do not remove the connector's protective cap until you are just about to connect the unit.
This will prevent potential contamination.
Unit features
}
Transponder technology for presence detection
}
Pilz coding type: fully coded
}
Dual-channel operation
}
2 safety outputs
}
LED display for:
– State of the actuator
– Supply voltage/fault
}
1 direction of actuation
}
5-pin M12 male connector