background image

PSEN cs1.19n

Operating Manual PSEN cs1.19n
1003269-EN-04

24

PSEN screw M5x10 10pcs Safety screws made from stainless steel with one-way slot

540 311

PSEN screw M5x20 10pcs Safety screws made from stainless steel with one-way slot

540 312

PSEN cs1/2 bracket cable

fix

Mechanical protection against defeat, protecting against unau-

thorised cable disconnection or damage for safety switches

PSENcode cs1/2, PSENcode cs5/6 M12, PSENslock

532 112

Cable

Product type

Connection 1

Connection 2

Length

Order No.

PSS67/PDP67 cable

M12-5sf

Straight, M12, 5-pin, socket Straight, M12, 5-pin,

connector

3 m

380 208

5 m

380 209

10 m

380 210

20 m

380 220

30 m

380 211

PSS67/PDP67 cable

M12-5af

Angled, M12, 5-pin, socket Angled, M12, 5-pin,

connector

3 m

380 212

5 m

380 213

10 m

380 214

30 m

380 215

PSEN cable M12-5sf

Straight, M12, 5-pin, socket Open cable

3 m

630 310

5 m

630 311

10 m

630 312

20 m

630 298

30 m

630 297

PSEN cable M12-5af

Angled, M12, 5-pin, socket Open cable

3 m

630 347

5 m

630 348

10 m

630 349

30 m

630 350

PDP67 F 8DI ION

Decentralised input module IP67 for PNOZmulti

773 600

EC declaration of conformity

This product/these products meet the requirements of the directive 2006/42/EC for ma-
chinery of the European Parliament and of the Council. The complete EC Declaration of
Conformity is available on the Internet at www.pilz.com/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost-
fildern, Germany

Summary of Contents for 540303

Page 1: ...PSEN cs1 19n Operating Manual 1003269 EN 04 PSEN sensor technology...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...y 8 Unit features 8 Function description 8 Block diagram 9 Operating distances 9 Lateral and vertical offset 10 Distance between actuators 11 Wiring 11 Pin assignment connector and cable 12 Connection...

Page 4: ...Contents Operating Manual PSEN cs1 19n 1003269 EN 04 4 EC declaration of conformity 24...

Page 5: ...rticularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive m...

Page 6: ...cs1 19 OSSD1 OSSD2 OSSD1 2 The safety level PL e Cat 4 SIL CL 3 see Safety related characteristic data 21 is only achieved if the safety outputs use 2 channel processing the actuators are used in acco...

Page 7: ...ices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibility...

Page 8: ...in Installation 14 If the original actuators are replaced with substitute actuators the ori ginal actuators must be destroyed before disposal Do not remove the connector s protective cap until you ar...

Page 9: ...22 LED OSSD1 LED OSSD2 OSSD1 High Low OSSD2 Low High OSSD1 2 High High Low Low Block diagram A1 A2 Power 12 22 Receiver Actuator OSSD1 Actuator OSSD1 2 Actuator OSSD2 Operating distances On Off Legen...

Page 10: ...tical offset Lateral offset Vertical offset 1 2 3 4 4 5 6 Power Fault Safety Gate Input 4 4 0 10 20 0 10 20 40 20 40 20 10 30 10 30 0 Legend 1 Hysteresis 2 Typical operating distance SO 3 Typical rele...

Page 11: ...oach the response range the max approach speed 18 Wiring Please note Information given in the Technical details must be followed The power supply must meet the regulations for extra low voltages with...

Page 12: ...channel2 Black 5 Do not connect Grey The wire colour also applies for the cable available from Pilz as an accessory Connection to evaluation devices Make sure that the selected evaluation device has t...

Page 13: ...ing with standard function block SB064 SB066 or FS_Safety Gate PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate The correct connection to the respective evaluation device...

Page 14: ...ve material Please check the oper ating distances and the assured release distance The safety switch and actuators should be installed opposite each other in parallel Make sure that all the actuators...

Page 15: ...h the printed side points towards the marking on the sensor 5 Do not fully tighten the second screw on the actuator 6 Align the safety switch and tighten the screws 7 Align the actuator and tighten th...

Page 16: ...of the sensor and evaluation device Error display through flashing codes The OSSD1 or OSSD2 LEDs send flash signals an error code can be established from the number and sequence The Power Fault LED il...

Page 17: ...cription Remedy 1 4 1 3x short 1x long 4x long 1x long 3x short Wiring error Rectify wiring error 1 12 3x short 1x long 12x long 3x short Wiring error Rectify wiring error 1 13 3x short 1x long 12x lo...

Page 18: ...asian FCC IC T V cULus Listed CE EAC Eurasian FCC IC T V cULus Listed Sensor s mode of opera tion Transponder Transponder Transponder Coding level in accord ance with EN ISO 14119 Low Low Low Design i...

Page 19: ...2 Switching current per out put 500 mA 500 mA 500 mA Breaking capacity per out put 12 W 12 W 12 W Potential isolation from system voltage No No No Short circuit proof yes yes yes Residual current at o...

Page 20: ...standard EN 60947 5 2 EN 60947 5 2 EN 60947 5 2 Frequency 10 55 Hz 10 55 Hz 10 55 Hz Amplitude 1 mm 1 mm 1 mm Shock stress In accordance with the standard EN 60947 5 2 EN 60947 5 2 EN 60947 5 2 Accele...

Page 21: ...follow installation guidelines Yes follow installation guidelines Yes follow installation guidelines Connection type M12 5 pin male con nector M12 5 pin male con nector M12 5 pin male con nector Mater...

Page 22: ...Diagnostics must detect stuck at faults and faults in the sensor supply lines e g shorts across contacts short circuits open circuits To do this a safety system must perform a feasibility check Each t...

Page 23: ...equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Le pr sent produit est conforme aux CNR...

Page 24: ...80 210 20 m 380 220 30 m 380 211 PSS67 PDP67 cable M12 5af Angled M12 5 pin socket Angled M12 5 pin connector 3 m 380 212 5 m 380 213 10 m 380 214 30 m 380 215 PSEN cable M12 5sf Straight M12 5 pin so...

Page 25: ...etyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document de...